background image

IBS Scherer GmbH 
Gewerbegebiet 
55599 Gau-Bickelheim 
Deutschland / Germany 
 

Tel.:  +49-6701-9383-0 
Fax   +49-6701-9383-33 
Mail:  

info@ibs-scherer.de

Web: 

www.ibs-scherer.de

 

 

General Manager: 
Axel Scherer, Dipl.-Ing. 
Registergericht Mainz 
HRB 32454 

 

IW/V3.0/23.10.2012/EN 

 
 
 

EC Declaration of Conformity 

as defined by Machinery Directive 2006/42/EC Annex II A 

 
 
Herewith we declare that the Parts Cleaner 
 

Article Type: 

BK 50 

Article-No.: 2120016 

 
conforms to the following Directives and Standards, when installed in accordance with the 
manufacturer’s specifications: 
 
EC Directives 

EC Machinery Directive 2006/42/EC 

 

Directive (2004/108/EC) relating to electromagnetic compatibility as amended 
on 2004/108/EG 

 

 

 

Applied Harmonised European Standards: 

 

 

EN ISO 12100 

Safety of machinery – General principles for design – Risk assessment and 
risk reduction 

EN 12921-1 

Machines for surface cleaning and pre-treatment of industrial items using 
liquids or vapours - Part 1: Common safety requirements 

EN 12921-3 

Machines for surface cleaning and pre-treatment of industrial items using 
liquids or vapours - Part 3: Safety of machines using flammable cleaning 
liquids 

EN 349:1993 + A1:2008  Safety of machinery -  

Minimum gaps to avoid crushing of parts of the human body 

EN 60 204-1 

Safety of machinery - Electrical equipment of machines - Part 1: General 
requirements 

ISO 11200:1995 

Noise emitted by machinery and equipment - Guidelines for the use of basic 
standards for the determination of emission sound pressure levels at a work 
station and at other specified positions; German version EN ISO 11200:1995  

 

 

 

Applied (German) Technical Specifications: 

 

 

BGI 180 (ZH1/562) 

Guidelines for the safety of equipment used for cleaning work pieces with 
liquid cleaning agents 

BGV A1 

Prevention Principles 

BGV A8 

Graphical safety and risk prevention symbols for use at the work place 

 

 
Authorized for collecting all technical documentation: 
Mr. Torsten Bodtländer, IBS-Scherer GmbH, Gewerbegebiet, 55599 Gau-
Bickelheim 

 
 
 
23.10.2012 ___________________________________ 
Date 

Axel Scherer, MSc. (General Manager) 

 

If the above named equipment is modified without our consent, this declaration is no longer valid. 

Summary of Contents for BK 50

Page 1: ...Translation Original Operating Instructions IBS Parts Cleaner Type BK 50 IW V4 0 10 2012 EN ...

Page 2: ...ting Instructions IBS Parts Cleaner Type BK 50 IW V4 0 10 2012 EN Page 2 IBS Scherer GmbH Head Office in Gau Bickelheim All devices have been tested and certified Please visit our website www ibs scherer de ...

Page 3: ...mbient Conditions 6 5 4 Connection Conditions 6 5 4 1 Prevention of electrostatic charge 7 5 4 1 1 Self priming pump 7 5 4 1 2 Parts Cleaning Device 7 5 5 Components Add Ons 7 5 5 1 IBS Catch Basins Type WK 50 optional 7 5 6 Waste Disposal 7 5 7 Operator Precautionary Measures 7 6 Operating the Machine 8 6 1 Machine Features 8 6 2 Assembling and Adjustment 8 6 2 1 Assembling the parts cleaning dev...

Page 4: ...hine parts motors and housings using IBS Special Cleaners 2 1 Approved Solvents Solvents used with this machine must not contain halogenated hydrocarbons and must meet the following requirements Device Type BK 50 IBS Special Cleaner Type EL Extra IBS Special Cleaner Type RF IBS Special Cleaner Type Purgasol NOTICE Please pay attention to the solvent s corresponding product information EC Safety Da...

Page 5: ...ia basin and drain connection back into the drum By a process of chemical separation the dirt and grease particles will sink to the bottom of the drum Once the cleaning effectiveness of the Special Cleaner is reduced the 50l solvent drum needs to be replaced IBS Scherer will take back used drums containing waste solvent and recycle the liquid providing the customer has not introduced other chemica...

Page 6: ...The crane must have a carrying capacity of at least 200 kg 4 2 2 Transport using a forklift Guide the forklift between the longitudinal braces of the wooden base of the pallet Lift the unit and transport it 5 Setup Startup________________________________________ 5 1 Securing the Unit Stability The unit must be placed in a level and stable location on a solvent resistant floor 5 2 Space Required Th...

Page 7: ...s etc should be disposed of in accordance with applicable environmental regulations Please contact IBS Scherer GmbH if you have any queries regarding disposal IBS Scherer will take back used drums containing waste solvent and recycle the liquid providing the customer has not introduced other chemical materials If you decide to use solvents by other manufacturers it is crucial that you follow the s...

Page 8: ...e that the outgoing lines for the pump 12 face to the left Insert the return hose 9 into the opening of the plug Secure the top end of the return hose 9 to the basin s drain connection piece 10 Attach the brush hose 11 to the pump 12 Guide the brush hose 11 through the round back wall opening of the basin 13 and insert the cleaning brush 14 into the hose Place the safety foot switch 7 in front of ...

Page 9: ...f use the cleaning liquid must be exchanged by means of changing the drum The unit must be disconnected from the power supply before the drum is changed Clean the unit regularly using a cloth and or cleaning solution Original replacement parts must be ordered from IBS Scherer GmbH otherwise the warranty will be void 8 Spare Parts and Accessories_________________________ The spare parts and accesso...

Page 10: ...21 3 Machines for surface cleaning and pre treatment of industrial items using liquids or vapours Part 3 Safety of machines using flammable cleaning liquids EN 349 1993 A1 2008 Safety of machinery Minimum gaps to avoid crushing of parts of the human body EN 60 204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements ISO 11200 1995 Noise emitted by machinery and equipm...

Reviews: