background image

Operating Instructions IBS-Parts Cleaner Type BK 50 (IW/V4.0/10-2012/EN) 

Page 

 

1. About the Machine / Technical Data _________________  

 

Dimensions and Performance Data   

Type BK 50 

External dimension device: 

 

 

Length:  

656 

mm 

Width:  

475 

mm 

Height:  

1075 

mm 

 

Working Area (inside dimension): 

 

646 x 465 mm 

Working height: 

 

815 mm 

 

 

 

Weight without drum: 

 

15 kg 

Weight with drum (full) 

 

60 kg 

Bearing capacity:  

 

50 kg 

Fill volume: 

 

50 l 

Noise emission value 
at work station: 

 

 
< 70 dB (A) 

Type class (according to EN 12921-3)

 

 

A1

Electrical Connection 

 

 

Power supply: 

 

1/N/PE 230 V ~ 

Frequency:  

50 

Hz 

Power draw: 

 

45 W – 0,2 A 

Max. back-up fuse 

 

6 A 

 

 

 

Pneumatic Conntection (Option) 

 

 

Pressure: 

 

max. 4 bar 

Pressure connection: 

 

1/8“ 

2. Proper use and foreseeable misuse __________________   

 

The IBS-Parts Cleaner Type BK 50 has been designed for cleaning oily and greasy metal parts (e.g. 
machine parts, motors and housings) using IBS-Special Cleaners.  

2.1.

 

Approved Solvents 

Solvents used with this machine must not contain halogenated hydrocarbons and must meet 
the following requirements: 
 
Device Type BK 50:

 

 

 

IBS Special Cleaner Type EL/Extra 

 

     IBS 

Special 

Cleaner 

Type 

RF 

 

     IBS 

Special 

Cleaner 

Type 

Purgasol 

 

NOTICE

 

Please pay attention to the solvent´s corresponding product information (EC Safety 
Data Sheet), before using solvents by other manufacturers. Prove in particular the 
compliance of the respective exposure limit value. 
 
Please take advice from IBS Scherer GmbH. Please also note additionally the notes 
under 2.2! 
 
The extended warranty of 3 applies only if IBS Special Cleaners are used.  

2.2.

 

Non-Approved Solvents 

 

 
The use of highly inflammable and inflammable liquids inside this machine is prohibited.  
The introduction of liquids with a flash point < 55°C, such as motor gasoline, is 
prohibited. 

DANGER

 

 
Please observe any relevant local and national legal requirements concerning the use of solvents for 
parts cleaning. 

Summary of Contents for BK 50

Page 1: ...Translation Original Operating Instructions IBS Parts Cleaner Type BK 50 IW V4 0 10 2012 EN ...

Page 2: ...ting Instructions IBS Parts Cleaner Type BK 50 IW V4 0 10 2012 EN Page 2 IBS Scherer GmbH Head Office in Gau Bickelheim All devices have been tested and certified Please visit our website www ibs scherer de ...

Page 3: ...mbient Conditions 6 5 4 Connection Conditions 6 5 4 1 Prevention of electrostatic charge 7 5 4 1 1 Self priming pump 7 5 4 1 2 Parts Cleaning Device 7 5 5 Components Add Ons 7 5 5 1 IBS Catch Basins Type WK 50 optional 7 5 6 Waste Disposal 7 5 7 Operator Precautionary Measures 7 6 Operating the Machine 8 6 1 Machine Features 8 6 2 Assembling and Adjustment 8 6 2 1 Assembling the parts cleaning dev...

Page 4: ...hine parts motors and housings using IBS Special Cleaners 2 1 Approved Solvents Solvents used with this machine must not contain halogenated hydrocarbons and must meet the following requirements Device Type BK 50 IBS Special Cleaner Type EL Extra IBS Special Cleaner Type RF IBS Special Cleaner Type Purgasol NOTICE Please pay attention to the solvent s corresponding product information EC Safety Da...

Page 5: ...ia basin and drain connection back into the drum By a process of chemical separation the dirt and grease particles will sink to the bottom of the drum Once the cleaning effectiveness of the Special Cleaner is reduced the 50l solvent drum needs to be replaced IBS Scherer will take back used drums containing waste solvent and recycle the liquid providing the customer has not introduced other chemica...

Page 6: ...The crane must have a carrying capacity of at least 200 kg 4 2 2 Transport using a forklift Guide the forklift between the longitudinal braces of the wooden base of the pallet Lift the unit and transport it 5 Setup Startup________________________________________ 5 1 Securing the Unit Stability The unit must be placed in a level and stable location on a solvent resistant floor 5 2 Space Required Th...

Page 7: ...s etc should be disposed of in accordance with applicable environmental regulations Please contact IBS Scherer GmbH if you have any queries regarding disposal IBS Scherer will take back used drums containing waste solvent and recycle the liquid providing the customer has not introduced other chemical materials If you decide to use solvents by other manufacturers it is crucial that you follow the s...

Page 8: ...e that the outgoing lines for the pump 12 face to the left Insert the return hose 9 into the opening of the plug Secure the top end of the return hose 9 to the basin s drain connection piece 10 Attach the brush hose 11 to the pump 12 Guide the brush hose 11 through the round back wall opening of the basin 13 and insert the cleaning brush 14 into the hose Place the safety foot switch 7 in front of ...

Page 9: ...f use the cleaning liquid must be exchanged by means of changing the drum The unit must be disconnected from the power supply before the drum is changed Clean the unit regularly using a cloth and or cleaning solution Original replacement parts must be ordered from IBS Scherer GmbH otherwise the warranty will be void 8 Spare Parts and Accessories_________________________ The spare parts and accesso...

Page 10: ...21 3 Machines for surface cleaning and pre treatment of industrial items using liquids or vapours Part 3 Safety of machines using flammable cleaning liquids EN 349 1993 A1 2008 Safety of machinery Minimum gaps to avoid crushing of parts of the human body EN 60 204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements ISO 11200 1995 Noise emitted by machinery and equipm...

Reviews: