background image

  MODEL

ITEM

  CAPACITY

  Voltage

  Current

  Frequency

  Protection

AC INPUT

DC 

INPUT

  Internal Battery

INVER

TER 

OUTPUT

  Wave Form

  Voltage

  Frequency

  Efficiency

  Type

  Voltage

  Current

C H G

  Transfer Time

  Back Up Time

  Indicator

  Operation Temperature

  Dimension

  Weight

UNIT

VA/W

V

A

Hz

A

V

Hz

%

V

A

ms

min

0

C

mm

Kg

SPECIFICATION

CE600D

CE1200D

600/300

1200/600

140 ~ 300

1.6

2.9

50 ± 3

3

5

Synthesized Sinewave (Step Wave)

230 ± 10%

50 ± 1

>80

Constant Voltage

13.5

27.0

1.5

7 ~ 20

LCD & Buzzer

0 ~ 40

298 x 101 x 142

353 x 150 x 162

4.5

5

8

10

1 x 12V/7.2Ah

2 x 12V/7.2Ah

REMARKS

Maximum

Max. Load & Charger

Fuse

Sealed Lead Acid 

Battery

PWM

Typical

Depending On  Load

Refer to Table of Status 

Indicator

D x W x H

Netto

Gross

4 ~ 8

III. TECHNICAL SPECIFICATION / 

SPESIFIKASI TEKNIS

Summary of Contents for CE 600D

Page 1: ...UNINTERRUPTIBLE POWER SUPPLY Ups USER S MANUAL BUKU PETUNJUK PEMAKAIAN CE 600D CE 1200D ICA CE SERIES Rev 01 481 11J0030 111...

Page 2: ...engatan listrik If the UPS has an internal energy source battery the output may be energized when the unit is not connected to a utility power outlet To deenergize a pluggable UPS press the OFF button...

Page 3: ...an terlalu rendah tinggi inverter seketika bekerja dengan waktu alih 4 ms sehingga pasokan listrik pada beban tidak terganggu terputus Dan bila listrik jala jala pulih maka otomatis beban mendapat day...

Page 4: ...V Hz V A ms min 0 C mm Kg SPECIFICATION CE600D CE1200D 600 300 1200 600 140 300 1 6 2 9 50 3 3 5 Synthesized Sinewave Step Wave 230 10 50 1 80 Constant Voltage 13 5 27 0 1 5 7 20 LCD Buzzer 0 40 298...

Page 5: ...n AC input voltage is abnormal this LCD symbol lights Saat tegangan input AC tidak normal simbol LCD ini menyala IV FRONT PANEL REAR PANEL VIEW TAMPAK PANEL DEPAN PANEL BELAKANG Battery capability Kem...

Page 6: ...high inverter converts the battery power to AC power automatically with transfer time 4 ms Buzzer will sound at interval 4 seconds if the line power off or 140V or 300V When the battery is near the e...

Page 7: ...bol pada posisi off dan tidak ada beban yang terpasang pada stopkontak keluaran 2 Hubungkan steker kabel daya ke stopkontak jala jala yang mempunyai arde 3 Hidupkan UPS dengan menekan tombol daya Bers...

Page 8: ...rger battery 10 hour by kept the main switch in on position when AC mains normal 3 Call for service SERVICE CENTRE ICA Jln Pinangsia Raya I No 22BB Jakarta 11120 Phone 021 6906020 Hunting ICA Notes Fo...