background image

Keselamatan Listrik

Electrical Safety

!

Do not work alone under hazardous 
conditions.

!

High current through conductive materials 
could cause severe burns.

!

Check that the power cord(s), plug(s), and 
socket are in good condition.

!

When grounding cannot be verified, 
disconnect the equipment from the utility 
power outlet before installing or 
connecting to other equipment. Reconnect 
the power cord only after all connections 
are made.

!

Connect the equipment to a three wire 
utility outlet (two pole plus ground). The 
receptacle must be connected to 
appropriate branch circuit/ mains 
protection (fuse or circuit breaker). 
Connection to any other type of receptacle 
may result in risk of electrical shock.

!

Jangan bekerja sendiri dalam situasi 
berbahaya.

!

Tegangan tinggi melalui bahan konduktif 
dapat menyebabkan luka bakar.

!

Periksa agar kabel listrik, fiting, dan soket 
berada dalam kondisi baik.

!

Bila grounding tak dapat diverifikasi, 
putuskan hubungan peralatan listrik 
dengan keluaran listrik AC sebelum 
memasang atau menghubungkannya 
dengan peralatan lain. Hubungkan kembali 
dengan kabel listrik hanya jika seluruhnya 
selesai dihubungkan.

!

Hubungkan peralatan ke keluaran listrik 
AC tiga kabel (dua kutub dan ground). 
Soket penerima harus terhubung secara 
benar melalui sirkuit cabang/ pelindung 
utama (sekring atau pemutus arus). 
Hubungan ke soket penerima dalam bentuk 
lainnya dapat menyebabkan bahaya 
sengatan listrik.

!

If the UPS has an internal energy source 
(battery), the output may be energized 
when the unit is not connected to a utility 
power outlet.

!

To deenergize a pluggable UPS, press the 
OFF button or switch to shut the equipment 
off. Unplug the UPS from the utility power 
outlet. Disconnect the external batteries 
where applicable and disconnect the 
internal battery. Push the ON button to 
deenergize the capacitors.

!

Jika alat memiliki sumber energi internal 
(baterai), output mungkin masih 
mengandung arus listrik walaupun unit 
tidak terhubung dengan tegangan listrik 
AC.

!

Untuk membuang arus listrik dari UPS 
yang terhubung, tekan tombol OFF untuk 
mematikan alat. Putuskan alat dari outlet 
listrik AC. Lepaskan batterai dan putuskan 
batterai internal. Tekan tombol ON untuk 
membuang listrik di dalam kapasitor.

!

Repair are to be performed only by 
qualified personnel.

!

Do not dispose of batteries in a fire. The 
batteries may explode.

!

Do not open or mutilate batteries. They 
contain an electrolyte that is toxic and 
harmful to the skin and eyes.

!

Replace batteries with the same number and 
type of batteries as originally installed in 
the equipment.

!

Perbaikan hanya dilakukan oleh seorang 
teknisi yang memiliki kualifikasi.

!

Jangan buang baterai ke dalam api, dapat 
meledak.

!

Jangan membongkar baterai. Baterai 
mengandung elektrolit yang beracun dan 
dapat merusak kulit dan mata.

!

Ganti baterai dengan nomor dan jenis yang 
sama seperti aslinya terpasang dalam alat.

Battery Safety

Keselamatan Baterai

Deenergizing Safety

Keselamatan Saat Membuang Arus Listrik

I. SAFETY NOTES / 

CATATAN KESELAMATAN

Summary of Contents for CE Series

Page 1: ...UNINTERRUPTIBLE POWER SUPPLY Ups USER S MANUAL BUKU PETUNJUK PEMAKAIAN CE 600 CE 1200 ICA CE SERIES Rev 05 481 11200D0 111...

Page 2: ...ngatan listrik If the UPS has an internal energy source battery the output may be energized when the unit is not connected to a utility power outlet To deenergize a pluggable UPS press the OFF button...

Page 3: ...an terlalu rendah tinggi inverter seketika bekerja dengan waktu alih 4 ms sehingga pasokan listrik pada beban tidak terganggu terputus Dan bila listrik jala jala pulih maka otomatis beban mendapat day...

Page 4: ...V A Hz A V Hz V A ms min 0 C mm Kg SPECIFICATION CE600 CE1200 600 300 1200 600 165 250 1 6 2 9 50 3 3 Synthesized Sinewave Step Wave 220 5 50 80 Constant Voltage 13 5 27 0 1 5 12 Led Buzzer 0 40 345 x...

Page 5: ...ekring Input 7 AC Cord Input Kabel Input AC To turn on and turn off the UPS Untuk menghidupkan dan mematikan UPS Indicate output UPS from line power Menunjukkan keluaran UPS dari listrik jala jala Ind...

Page 6: ...high inverter converts the battery power to AC power automatically with transfer time 4 ms Buzzer will sound at interval 4 seconds if the line power off or 165V or 250V When the battery is near the e...

Page 7: ...e UPS into the UPS 1 Pastikan tombol pada posisi off dan tidak ada beban yang terpasang pada stopkontak keluaran 2 Hubungkan steker kabel daya ke stopkontak jala jala yang mempunyai arde 3 Hidupkan UP...

Page 8: ...arger battery 10 hour by kept the main switch in on position when AC mains normal 3 Call for service SERVICE CENTRE ICA Jln Pinangsia Raya I No 22BB Jakarta 11120 Phone 021 6906020 Hunting ICA Notes F...

Reviews: