background image

UPS (Uninterruptible Power Supplies) can 

provide full protection against all of power 
problem for your sensitive equipment ranging 
from computer, computerized instrument, 
PABX, facsimile, cash register to all electronic 
equipment.

This UPS consists of inverter, batteries, 

battery charger, control circuit, stabilizer, 
transfer switch and indicator. When line power 
is normal, the UPS filters line power input and 
by pass to output UPS and at the same time the 
batteries is being charged by battery charger. 
And when line power fails (off, voltage too 
low/high), inverter will supply regulated AC 
power to the load within ≤4 ms transfer time 
so that the power supplied to the load is 
uninterrupted. And when line power is normal 
automatically load gets from line power again.

UPS (Uninterruptible Power Supplies) 

dapat melindungi peralatan anda yang rentan 
terhadap gangguan kelistrikan seperti: 
komputer, instrument terkomputerisasi, PABX, 
faksimili, cash register dan peralatan 
elektronik lainnya.

UPS ini terdiri atas inverter, baterai, pengisi 

baterai, rangkaian pengendali, stabilisator, 
saklar-pengalih dan indikator. Saat listrik jala-
jala normal, UPS menyaring listrik masukan 
dan menyalurkannya pada keluaran UPS, pada 
saat yang sama baterai diisi oleh pengisi 
baterai. Manakala terjadi gangguan listrik 
(padam, tegangan terlalu rendah/tinggi), 
inverter seketika bekerja dengan waktu alih ≤4 
ms sehingga pasokan listrik pada beban tidak 
terganggu/terputus. Dan bila listrik jala-jala 
pulih maka otomatis beban mendapat daya 
listrik jala-jala kembali.

BATTERY

CHARGER

INVERTER

TRANSFER

SWITCH

UPS OUTPUT

AC INPUT

INDICATOR

&

CONTROL CIRCUIT

STABILIZER

II. INTRODUCTION / 

PENDAHULUAN

Jangan buang sisa kemasan produk ini sebagai 
limbah rumah tangga: Bawa ke tempat 
pengumpulan untuk didaur ulang. 
Untuk informasi tentang tempat daur ulang 
terdekat, hubungi petugas pembuangan limbah 
setempat.

Pembuangan produk

UPS berisi bahan internal yang (dalam kasus 
pembuangan) dianggap LIMBAH BERACUN 
dan BERBAHAYA, seperti papan sirkuit 
elektronik dan baterai. Perlakukan bahan-bahan 
ini sesuai dengan undang-undang yang berlaku 
dengan merujuk pada personel servis yang 
berkualifikasi. Pembuangan yang tepat 
berkontribusi untuk menghormati lingkungan 
dan kesehatan manusia.

Disposing of the product

The UPS contains internal material that (in case 
of disposal) are considered TOXIC and 
HAZARDOUS WASTE, such as electronic 
circuit boards and batteries. Treat these 
materials according to the laws applicable 
referring to qualified service personnel. Their 
proper disposal contributes to respect the 
environment and human health.

Do not dispose of leftover packaging for this 
product as household waste: Take it to a 
collection point for recycling.
For information about the nearest recycling 
facility, contact your local waste disposal 
authority.

Summary of Contents for CE Series

Page 1: ...UNINTERRUPTIBLE POWER SUPPLY Ups USER S MANUAL BUKU PETUNJUK PEMAKAIAN CE 600 CE 1200 ICA CE SERIES Rev 05 481 11200D0 111...

Page 2: ...ngatan listrik If the UPS has an internal energy source battery the output may be energized when the unit is not connected to a utility power outlet To deenergize a pluggable UPS press the OFF button...

Page 3: ...an terlalu rendah tinggi inverter seketika bekerja dengan waktu alih 4 ms sehingga pasokan listrik pada beban tidak terganggu terputus Dan bila listrik jala jala pulih maka otomatis beban mendapat day...

Page 4: ...V A Hz A V Hz V A ms min 0 C mm Kg SPECIFICATION CE600 CE1200 600 300 1200 600 165 250 1 6 2 9 50 3 3 Synthesized Sinewave Step Wave 220 5 50 80 Constant Voltage 13 5 27 0 1 5 12 Led Buzzer 0 40 345 x...

Page 5: ...ekring Input 7 AC Cord Input Kabel Input AC To turn on and turn off the UPS Untuk menghidupkan dan mematikan UPS Indicate output UPS from line power Menunjukkan keluaran UPS dari listrik jala jala Ind...

Page 6: ...high inverter converts the battery power to AC power automatically with transfer time 4 ms Buzzer will sound at interval 4 seconds if the line power off or 165V or 250V When the battery is near the e...

Page 7: ...e UPS into the UPS 1 Pastikan tombol pada posisi off dan tidak ada beban yang terpasang pada stopkontak keluaran 2 Hubungkan steker kabel daya ke stopkontak jala jala yang mempunyai arde 3 Hidupkan UP...

Page 8: ...arger battery 10 hour by kept the main switch in on position when AC mains normal 3 Call for service SERVICE CENTRE ICA Jln Pinangsia Raya I No 22BB Jakarta 11120 Phone 021 6906020 Hunting ICA Notes F...

Reviews: