IV. SAFETY NOTES / 

CATATAN KESELAMATAN

!

!

!

!

!

Do not work alone under hazardous 
conditions.
High current through conductive materials 
could cause severe burns.
Check that the power cord(s), plug(s), and 
socket are in good condition.
When grounding cannot be verified, 
disconnect the equipment from the utility 
power outlet before installing or connecting 
to other equipment. Reconnect the power 
cord only after all connections are made.
Connect the equipment to a three wire 
utility outlet (two pole plus ground). The 
receptacle must be connected to appropriate 
branch circuit/ mains protection (fuse or 
circuit breaker). Connection to any other 
type of receptacle may result in risk of 
electrical shock.

!

!

!

!

!

Jangan bekerja sendiri dalam situasi 
berbahaya.

Tegangan tinggi melalui bahan konduktif 
dapat menyebabkan luka bakar.
Periksa agar kabel listrik, fiting, dan soket 
berada dalam kondisi baik.
Bila grounding tak dapat diverifikasi, 
putuskan hubungan peralatan listrik dengan 
keluaran listrik AC sebelum memasang atau 
menghubungkannya dengan peralatan lain. 
Hubungkan kembali dengan kabel listrik 
hanya jika seluruhnya selesai dihubungkan.

Hubungkan peralatan ke keluaran listrik AC 
tiga kabel (dua kutub dan ground). Soket 
penerima harus terhubung secara benar 
melalui sirkuit cabang/ pelindung utama 
(sekring atau pemutus arus). Hubungan ke 
soket penerima dalam bentuk lainnya dapat 
menyebabkan bahaya sengatan listrik.

!

!

If the UPS has an internal energy source 
(battery), the output may be energized when 
the unit is not connected to a utility power 
outlet.
To deenergize a pluggable UPS, press the 
OFF button or switch to shut the equipment 
off. Unplug the UPS from the utility power 
outlet. Disconnect the external batteries 
where applicable and disconnect the internal 
battery. Push the ON button to deenergize 
the capacitors.

!

!

Jika alat memiliki sumber energi internal 
(batterai), output mungkin masih 
mengandung arus listrik walaupun unit tidak 
terhubung dengan tegangan listrik AC.
Untuk membuang arus listrik dari UPS yang 
terhubung, tekan tombol OFF untuk 
mematikan alat. Putuskan alat dari outlet 
listrik AC. Lepaskan batterai dan putuskan 
batterai internal. Tekan tombol ON untuk 
membuang listrik di dalam kapasitor.

!

!

!

!

Repair are to be performed only by qualified 
personnel.
Do not dispose of batteries in a fire. The 
batteries may explode.
Do not open or mutilate batteries. They 
contain an electrolyte that is toxic and 
harmful to the skin and eyes.
Replace batteries with the same number and 
type of batteries as originally installed in the 
equipment.

!

!

!

!

Perbaikan hanya dilakukan oleh seorang 
teknisi yang memiliki kualifikasi.
Jangan buang batterai ke dalam api, dapat 
meledak.
Jangan membongkar batterai. Batterai 
mengandung elektrolit yang beracun dan 
dapat merusak kulit dan mata.
Ganti batterai dengan nomor dan jenis yang 
sama seperti aslinya terpasang dalam alat.

Battery Safety

Keselamatan Batterai

Deenergizing Safety

Keselamatan Saat Membuang Arus Listrik

Summary of Contents for CN Series

Page 1: ...UNINTERRUPTIBLE POWER SUPPLY ICA 481 11J0010 111 REV 04...

Page 2: ...h maka otomatis beban mendapat daya listrik jala jala kembali UPS Uninterruptible Power Supplies can provide full protection against all of power problem for your sensitive equipment ranging from comp...

Page 3: ...ure Dimension Weight UNIT VA W V A Hz A V Hz V A ms min 0 C mm Kg SPECIFICATION CN650 CN1300 650 325 1300 650 140 300 1 6 2 9 50 3 3 5 Synthesized Sinewave Step Wave 220 5 50 3 80 Constant Voltage 13...

Page 4: ...nghidupkan dan mematikan UPS Led Hijau Menunjukkan keluaran UPS dari listrik jala jala Led Kuning Menunjukkan keluaran UPS dari inverter Led Merah Menunjukkan keadaan beban lebih ketidak Normalan Stop...

Page 5: ...nnya dapat menyebabkan bahaya sengatan listrik If the UPS has an internal energy source battery the output may be energized when the unit is not connected to a utility power outlet To deenergize a plu...

Page 6: ...ing charged whenever it is connected to utility power and UPS must be turn ON V UPS INSTALLATION PEMASANGAN UPS VI OPERATION PROCEDURE CARA PENGOPERASIAN 1 Buka kemasan dan Pemeriksaan Buka kemasan da...

Page 7: ...ali steker maka sekitar 2 detik kemudian led kuning INVERTER padam sedangkan led hijau akan menyala 6 Sekarang UPS siap menjalankan fungsinya Hubungkan peralatan yang akan diberi pasokan daya pada sto...

Page 8: ...voltage 140 Vac turn on main switch red led light on after 5 seconds go out but inverter does not work When AC main failure and inverter does not work 1 Main voltage 140 Vac or 300 Vac 2 Problem in t...

Reviews: