18
seated into the terminal block header, and route the network cable such
that it is located well away from any electrical noise sources, such as ASD
input power or motor wiring. Also take care to route the cable away from
any sharp edges or positions where it may be pinched.
8. If an auxiliary power supply is going to be used, connect it to the
gateway’s “Power” jack.
9. Take a moment to verify that the gateway and all primary and secondary
network cables have sufficient clearance from drives, motors, or power-
carrying electrical wiring.
10. Turn the power sources to all connected drives ON, and verify that the
drives function properly. If the drives do not appear to power up, or do not
function properly, immediately turn power OFF.
Repeat steps 1 and 2 to
remove all power from the drives.
Then, verify all connections. Contact
ICC or your local Toshiba representative for assistance if the problem
persists.