159
ICC
To access the gateway’s embedded web server, either use the finder tab in the
configuration utility (refer to section
8.2) and select the “Open Web Interface”
button when the target unit is highlighted, or just directly enter the target unit’s IP
address into the address (URL) field of your web browser. Refer to Figure 23 for
a representative screenshot of the web server interface.
In order to access the web server and view the parameter values, destination
TCP ports 80 and 2000 must be accessible from the client computer. If an “XML
socket connection failed” error message is displayed in the activity window, and
no parameter values are shown, this is typically indicative of port 2000 being
blocked by a firewall or Ethernet router situated between the client computer and
the gateway.
10.2
Authentication
For security, the gateway requires valid user authentication whenever the web
page is accessed. The authentication request will appear as a browser popup
box that will request entry of a user name and password. Refer to Figure 24.
Figure 24: Web Server Authentication
The factory-default user name is “root”, and the password is “icc”. Note that the
username and password are case-sensitive, and that once authenticated, the
authentication will remain in effect from that point until all browser windows are
closed. The authentication credentials can also be changed from their default
settings (refer to section 8.7.1.1.)