83
Parameter
Function / Title Bank
Mask
Adjustment Range
Multiplier
0133
STALL PROTECTION
ENABLE
0 / 1
0040
0000: ON
(0)
0040: OFF
(1)
⎯
0134
0
STALL
PROTECTION
CURRENT LEVEL
0 / 1
00FF
000A
∼
00D7 (10
∼
215)
1
0135
UNDERVOLTAGE TRIP
SELECTION
0 / 1
0080
0000: Trip disabled
(0)
0080: Trip (during run)
(1)
⎯
0136
UNDERVOLTAGE DETECT
TIME
0 / 1
FFFF
0000
∼
03E8 (0.00
∼
10.00)
0.01
0137
LOW CURRENT DETECT
SELECTION
0 / 1
0008
0000: Trip disabled
(0)
0008: Trip on detection
(1)
⎯
0138
LOW CURRENT DETECT
LEVEL
0 / 1
00FF
0000
∼
0064 (0
∼
100)
1
0139
LOW CURRENT
DETECTION TIME
0 / 1
00FF
0000
∼
00FF (0
∼
255)
1
0140
OUTPUT SHORT-
CIRCUIT DETECTION
SELECT
0 / 1
0003
0000: Standard motor
(0)
0001: High-speed
motor
(1)
0002: Positioning use (standard
motor) (2)
0003: Positioning use (high-speed
motor) (3)
⎯
0141
OVERTORQUE TRIP
SELECTION
0 / 1
0040
0000: Trip disabled
(0)
0040: Trip enabled
(1)
⎯
0142
OVERTORQUE TRIP
LEVEL
0 / 1
00FF
0000
∼
00C8 (0
∼
200)
1
0143
FAULT TRIP EEPROM
SAVE ENABLE
0 / 1
0002
0000: Data cleared when powered
OFF (0)
0002: Data retained when powered
OFF (1)
⎯
0144
COOLING FAN CONTROL
SELECTION
0 / 1
0004
0000: Automatic (temperature
detection) (0)
0004: Always
ON
(1)
⎯
0145
CUMULATIVE RUN
TIMER ALARM SETTING
0 / 1
FFFF
0000
∼
C34B (0.00
∼
999.90)
0.02
Summary of Contents for ETH-200
Page 101: ...100 18 Notes...
Page 102: ...101...