9.1 Reset for overtemperature

The equipment has a separate safety device to prevent that the heating element tem

-

perature rises uncontrolled, for example, when it runs out of water.

In that case, the mechanism disconnects the heating element power and, once cooled, 

it must be reset in order to continue using the computer.

Press the reset button on the back side of the computer.

9.2 Setting the «Offset» temperature reading

The offset (A) and the ºC/ºF unit (B) can be adjusted.

A. Adjust the probe reading correction (offset)

Press keys (2) and (3) continuously and at the same time (about 5 seconds). 

The 

OFFs

 message will appear.

Use keys (2) / (3) to set the actual temperature reading value. Press key (1) 

to confirm.

B. Presentation unit: ºC / ºF

Press keys (2) and (3) continuously and at the same time (about 5 seconds). 

The 

OFFs

 message will appear.

Press the key (4). The message 

Unit

 will appear. Using keys (2) / (3), select the 

unit: ºC / ºF. Confirm with key (1).

10. WARRANTY

This product is guaranteed for one year. It does not cover damages caused by an incorrect 

use or causes beyond the control of ICC.

Any manipulation of the equipment by personnel not authorized by ICC automatically 

cancels the guarantee.

Description

Cause

Resolution

It does not heat

The safety thermostat has skipped

Press the thermostat reset. See 9.1

Heating element is melted

Contact the technical service to replace

Temperature reading does 

not match the external ther

-

mometer

Temperature imbalance

See 9.2 on how to act for adjustment

9. ERROR MESSAGES & TROUBLESHOOTING

 

P.FAIL 

Power failure. The equipment continues with the process.

Err

 will appear in green on the top line of the display. 

(Note: if you turn off the device without pressing STOP, this error will appear when 

the device is restarted)

TSEG

 

The safety thermostat is open. 

SENS

 

Open temperature probe. 

  

The control does not detect the temperature probe. 

HEAT

 

The resistance does not work. 

  

The equipment detects that the temperature does not increase.

Summary of Contents for RONER

Page 1: ...Pag 1 J P SELECTA s a u Autov a A 2 Km 585 1 Abrera 08630 Barcelona Espa a Tel 34 937 700 877 Fax 34 937 702 362 e mail selecta jpselecta es website http www grupo selecta com RONER 80013 230V 80015...

Page 2: ...stencia Heating element Termostato seguridad Safety thermostat Cable alimentaci n Power cord Nuez de fijaci n Fixing nut Indice 1 COMPONENTES COMPONENTS 2 2 INFORMACI N GENERAL Y SEGURIDAD 3 3 DESCRIP...

Page 3: ...e indirectas Pasteurizaci n 85 C de elaboraciones cocinadas con t cnicas tradicionales Regeneraci n t rmica de elaboraciones acabadas y envasadas al vac o Ideal como ba o mar a para calentar con contr...

Page 4: ...zador verde el de arriba 4 Pulsar la tecla 4 si desea seleccionar un tiempo de funcionamiento 5 Pulsar la tecla 1 para iniciar el ciclo 6 El tiempo de cuenta atr s empezar a contar en cuanto se alcanc...

Page 5: ...utorizado puede provocar da os de dif cil reparaci n Consulte al servicio t cnico autorizado de ICC LIMPIEZA Para la limpieza de las partes accesibles del equipo utilice limpiacristales o un producto...

Page 6: ...forma continuada unos 5 segundos Apa recer el mensaje OFFs Pulsar la tecla 4 Aparecer el mensaje Unit Mediante las teclas 2 3 seleccionar la unidad C F Confirmar con la tecla 1 10 GARANT A Este produ...

Page 7: ...on and set time Direct and indirect cookings are performed Pasteurization 85 C of food products cooked with traditional techniques Thermal regeneration of finished food products cooked and vacuum pack...

Page 8: ...ture value is selected in the green display the above one 4 Press key 4 if you want to select an operating time 5 Press key 1 to start the cycle 6 The countdown time will start counting as soon as the...

Page 9: ...bit lowered 8 TECHNICAL SPECIFICATIONS Reference code 80013 80015 Dimensions height width depth mm 280 180 190 Supply voltage 230 VAC 50 60 Hz 115 VAC 50 60Hz Electrical power W 2060 1060 Weight Kg 4...

Page 10: ...the same time about 5 seconds The OFFs message will appear Press the key 4 The message Unit will appear Using keys 2 3 select the unit C F Confirm with key 1 10 WARRANTY This product is guaranteed fo...

Reviews: