I. Adjust the driving depth
Caution !
• Please READ and UNDERSTAND
the section 1 “General Safety
Instructions” for personal and
working environment safety.
• Never press the pin guide by bare
hand or by any parts of the body.
• Never point the tools at anybody.
Steps:
Adjust the knurled depth
setting dial located at the front of the
tool clockwise (+) to increase the driving
depth, counter-clockwise (-) to decrease
the driving depth.
NOTE:
• Do not over adjust the knurled depth
setting dial, the threaded pin should
be visible and protrude out from the
end of the Dial.
J. Cleaning Filter
The filter at the back of the tool acts
crucially to suck in air into the chamber.
For maintaining the best performance
of the tool users should always keep it
clean.
1. Unscrew four screws on the back
cover
2. Take out the back cover and clean
the mesh with brush or air.
3. Put the back cover on the machine
and fasten with four screws.
NOTE:
• Do not attempt to use water to
clean the mesh. The cover and
mesh must be dry when operating
the tool. If wet it may easily cause
malfunction to the tool.
Preparing Tool for Operation - Battery/
Charger Problems
SYMPTOM 1
Battery Cell does not appear to accept
charge. Green charger light does not
come on after several hours.
SYMPTOM 2
Red and green LEDs on charger are
blinking alternately.
Possible
reasons
Services
Inoperative
indicator
lights on
charger.
Try Battery in tool
after 3 hours on
charge cycle. If tool
functions properly
charger lights are not
working correctly.
Replace charger,
or monitor time to
ensure Battery Cell
has adequate time for
recharging. It’s normal
for Battery to feel
warm after properly
charging.
Damaged
charger.
Discontinue use
immediately and
unplug from power
source.
Replace charger and
tag or dispose of
charger to prevent
accidental reuse or
connection to power
source.
4 - TROUBLESHOOTING
Preparing Tool for Operation - Battery/