5.3 Pre-Combustion / Combustion
Stage Of Operation
SYMPTOM 1
Contact Arm does not depress fully, tool does not
operate.
Possible reasons
Services
Lockout Bar is
stuck in lockout
position.
Check if there is not
enough pins in the channel,
load extra pins according to
Operating Manual.
The nose piece
is bent, or the
channel is stuck
with dirt.
Inspect if the nose piece
and channel is clean. If
it is damaged, consult
authorized service agent
for repair and replacement
of the parts.
Follower holder
positions wrongly
at the top of
the magazine
strip.
Slide the follower holder
to the bottom and release
gently.
Cylinder head
O-Ring pinched.
Contact authorized service
agent for repair.
Jammed fasteners. Clear jam according to User
Manual.
SYMPTOM 2
Failure to install fasteners to nose piece.
Possible reasons
Services
Piston positioned
wrongly.
Return piston to original
position with a rod or
screwdriver.
O-Ring is
damaged and
causing leakage
of gas.
Contact authorized service
agent for repair.
Damaged valve
plate or reed of
the cylinder body.
Contact authorized service
agent for repair.
SYMPTOM 3
Tool will not cycle - fan runs.
Possible reasons
Services
Fuel Cell is empty.
Replace Fuel Cell.
Spark does not
occur.
Contact authorized service
agent for repair.
SYMPTOM 4
Fail to drive fasteners.
Possible reasons
Services
Water vapour
surrounding spark
causing short
circuit.
Dry the spark area or
contact authorized service
agent for repair.
Sealing ring
damaged.
Contact authorized service
agent for repair.
Piston guide stuck
with dirts.
Contact authorized service
agent for repair.
5.4 Power / Exhaust Stage Of
Operation
SYMPTOM 1
Tool operates properly, but fasteners do not drive
fully.
Possible reasons
Services
Battery is
discharged.
Charge battery.
Fuel Cell is low.
Replace fuel cell according