operating & maintenance manual
–
console water source heat pump (wshp)
4
•
Your
ICE AIR
unit must be properly installed and
commissioned to operate correctly. Improper unit
installation, adjustment or commissioning, and / or
improper piping installation and connection can lead
to equipment malfunction and hazardous operating
conditions, and may void your Warranty.
If you have any doubt about the proper installation
of your WSHP unit, please contact your property
manager at once to have a qualified technician
inspect the equipment. Do NOT operate the
equipment when in doubt – have it inspected first!
•
Your
ICE AIR
equipment is covered by a
manufacturer’s Warranty (see Warranty Information
Sheet for full terms and conditions). Your unit(s) must
be properly installed and kept free of obstructions.
Additionally, proper cleaning of the unit filter,
evaporator coil and all air flow areas must be
maintained. Failure to do so will decrease unit
function and efficiency, and may void your Warranty.
electrical Data
•
Ensure that available power is the same voltage and
phase as indicated on the unit serial plate. Line and
voltage wiring must be executed in accordance with
local codes or to the National Electrical Code or in
Canada to Canadian Electrical Standards (whichever
is applicable).
•
Apply correct line voltage to unit. Disconnect switch
near unit is required by code. Power to unit must
be sized correctly and have dual element class RK5
fuses or HACR circuit breaker for branch circuit
overcurrent protection. Consult the unit serial plate
for current ratings.
•
All 208/230V units are wired for 208V operation
unless otherwise specified.
The following physical conditions must be maintained for
proper unit operation:
•
Unobstructed air flow into and out of the unit room
enclosure (cabinet).
Therefore:
- Do not place furniture, rugs or objects directly
in front of, underneath or against the unit
cabinet front.
- Do not place plants, fabrics or objects on top
of or blocking the enclosure discharge grille
(at the cabinet top).
- Do not block the top of the cabinet with drapes
or curtains. To ensure proper cooling and
heating, drapes and curtains should be opened
or positioned so that the air discharge from
the unit does not flow behind these window
treatments.
- Have the unit filter properly cleaned and
serviced to prevent air blockage from dirt
and dust within the filter media.
•
Proper installation and operating environment must
be maintained.
Therefore:
- Do not operate the unit in corrosive environ-
ments such as chemical plants, refineries or
salt spray areas.
- Operate only with proper electrical service and
protective circuit breakers or fuses in place.
- Operate only with all chassis and enclosure
sheet metal parts in place and properly
installed.
- In areas of high concentrations of dirt, dust,
pet dander or pollutants, clean the filter often
(at least monthly).
- Do not clean the unit with any solvents or
cleaning solutions that may damage the
equipment (see maintenance Instructions
for proper cleaning protocols).
- Understand and follow the unit operating
instructions below before using your WSHP
equipment.