background image

operating & maintenance manual

 – 

console water source heat pump (wshp)

4

• 

Your 

ICE AIR

 unit must be properly installed and 

commissioned to operate correctly. Improper unit 

installation, adjustment or commissioning, and / or 

improper piping installation and connection can lead 

to equipment malfunction and hazardous operating 

conditions, and may void your Warranty.  

If you have any doubt about the proper installation  

of your WSHP unit, please contact your property 

manager at once to have a qualified technician 

inspect the equipment. Do NOT operate the  

equipment when in doubt – have it inspected first! 

• 

Your 

ICE AIR

 equipment is covered by a  

manufacturer’s Warranty (see Warranty Information 

Sheet for full terms and conditions). Your unit(s) must 

be properly installed and kept free of obstructions.  

Additionally, proper cleaning of the unit filter,  

evaporator coil and all air flow areas must be  

maintained. Failure to do so will decrease unit  

function and efficiency, and may void your Warranty.

electrical Data

• 

Ensure that available power is the same voltage and 

phase as indicated on the unit serial plate. Line and 

voltage wiring must be executed in accordance with 

local codes or to the National Electrical Code or in 

Canada to Canadian Electrical Standards (whichever 

is applicable). 

• 

Apply correct line voltage to unit. Disconnect switch 

near unit is required by code. Power to unit must 

be sized correctly and have dual element class RK5 

fuses or HACR circuit breaker for branch circuit 

overcurrent protection. Consult the unit serial plate 

for current ratings. 

• 

All 208/230V units are wired for 208V operation  

unless otherwise specified.

The following physical conditions must be maintained for 

proper unit operation: 

• 

Unobstructed air flow into and out of the unit room 

enclosure (cabinet). 

Therefore:

- Do not place furniture, rugs or objects directly    

  in front of, underneath or against the unit  

  cabinet front.

- Do not place plants, fabrics or objects on top  

  of or blocking the enclosure discharge grille  

  (at the cabinet top).

- Do not block the top of the cabinet with drapes 

  or curtains. To ensure proper cooling and  

  heating, drapes and curtains should be opened 

  or positioned so that the air discharge from  

  the unit does not flow behind these window 

  treatments.

- Have the unit filter properly cleaned and  

  serviced to prevent air blockage from dirt  

  and dust within the filter media.  

• 

Proper installation and operating environment must 

be maintained. 

 

Therefore:

- Do not operate the unit in corrosive environ- 

  ments such as chemical plants, refineries or 

  salt spray areas.

- Operate only with proper electrical service and 

  protective circuit breakers or fuses in place.

- Operate only with all chassis and enclosure 

  sheet metal parts in place and properly  

  installed.

- In areas of high concentrations of dirt, dust, 

  pet dander or pollutants, clean the filter often 

  (at least monthly). 

- Do not clean the unit with any solvents or  

  cleaning solutions that may damage the  

  equipment (see maintenance Instructions  

  for proper cleaning protocols).

- Understand and follow the unit operating  

  instructions below before using your WSHP 

  equipment. 

Summary of Contents for Console Water Source Heat Pump

Page 1: ...Console Water Source Heat Pump WSHP OPERATING MAINTENANCE MANUAL World class comfort ...

Page 2: ... 14 1 4 SECTION G G SCALE 1 10 HOLE FOR DRAIN HOSE JUNCTION BOX FRONT VIEW NOTES DIMENSIONS ARE SHOWN IN INCHES 1 OPTIONAL MOTORIZED WATER VALVE IS SHOWN 2 ALL DIMENSIONS ARE 1 4 3 LEFT HAND CONFIGURATION IS SHOWN 4 UNIT IS SHIPPED WITH UNIVERSAL LEFT HAND OR RIGHT HAND 5 PIPING CAPABILITY 6 OPTIONAL OUTSIDE AIR DOOR SHOWN 7 SUPPLY AND RETURN PIPES HAVE 1 2 THREADED FEMALE ADAPTER A B C D E 5HPW09...

Page 3: ...ed in a separate instruction sheet specific to that option On behalf of ICE AIR and our network of distributors and dealers we are happy to welcome you to our base of satisfied customers CONSUMER SAFETY AND OPERATING NOTES FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE AIR WSHP UNIT PLEASE READ THE FOLLOWING CONSUMER SAFETY AND OPERATING NOTES CAREFULLY BEFORE OPERATING YOUR EQUIPMENT This unit MUST b...

Page 4: ...circuit breaker for branch circuit overcurrent protection Consult the unit serial plate for current ratings All 208 230V units are wired for 208V operation unless otherwise specified The following physical conditions must be maintained for proper unit operation Unobstructed air flow into and out of the unit room enclosure cabinet Therefore Do not place furniture rugs or objects directly in front o...

Page 5: ...Power Control Board PCB The large LCD display panel includes clearly marked control buttons The Control pad is a programmable user friendly device that enables the user to program desired temperature settings and operational modes LCD Programmable Thermostat Feature list Operates on 2 stage Heat and 2 stage Cool 7 programs Mo Tu We Th Fr Sa Su or 5 2 programs Mo Fr Sa Su 4 Separate Time and Temper...

Page 6: ...perature The unit will cycle until the set temperature is achieved and then will continuously cycle to maintain the set temperature The temperature reading that is on constant display is the ambient room temperature EVENT TIME HEAT COOL MON FRI WAKE leave return SLEEP 6 00 AM 8 00 AM 6 00 PM 10 00 PM 70º F 21º C 62º F 17º C 70º F 21º C 62º F 17º C 78º F 26º C 85º F 29 5º C 78º F 26º C 82º F 28º C ...

Page 7: ...an when complete The cool limit setting should be at least 4 F higher than the heat limit setting The cool limit setting is 55 F to 95 F The heat limit setting is 51 F to 91 F Exit Internal Setting and Return to Normal Mode 1 Press Fan to confirm and return to normal mode 2 If no key is pressed for 15 seconds it will return to normal mode automatically Temporary Program Override 1 When thermostat ...

Page 8: ...anual assumes that your WSHP unit has been installed by a qualified installation professional and is operating properly prior to maintenance service Have your unit periodically inspected by a properly trained service professional or building maintenance staff person The unit should be checked for the safe and proper functioning of all of its systems at least once a year The following recommended m...

Page 9: ...n a facility properly equipped to handle this type of work in a safe and professional manner Drain Pan Drain Hose Cleaning The condensate pan is located directly under the evaporator coil Check the visible section of the interior of the drain pan for any buildup of dirt or condensate water Wash annually to remove all dirt build up Check condensate drain pan for algae growth every 2 to 3 months If ...

Page 10: ...east once a month Pay special attention to hose assemblies and connections Repair any leaks and replace deteriorated hose immediately to avoid potential costly damage to your property due to component failure TROUBLESHOOTING 1 If unit is not operating conduct the following checks If a flashing A appears on the display contact a trained technician Check the electrical connections Check the voltage ...

Page 11: ...ed Normal Off On Off High Pressure Off Off Flash Low Pressure Flash Off Off Evaporator too cold Flash Off Flash Coaxial winter protection Flash on off Temperature probe failure Off flash Off High low voltage Off Off On Condensate over flow on Off Off Coaxial water too cold on Off flash troubleshooting error code menu ...

Page 12: ...RES MUST BE SERVICED BY QUALIFIED TRAINED PERSONNEL ELECTRIC SHOCK HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING MOVING PARTS HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING UNIT MUST BE OPERATED WITH ALL CHASSIS SHEET METAL PARTS PROPERLY IN PLACE UNIT MUST BE OPERATED WITH ALL ENCLOSURE CABINET PARTS IN PLACE READ THIS ENTIRE OPERATIONS MANUAL BEFORE OPERATING THE U...

Reviews: