OPERATING & MAINTENANCE MANUAL

 

 

PACKAGED TERMINAL AIR CONDITIONER (PTAC) – RSAN

2

WELCOME

Congratulations on your selection of ICE AIR  
Packaged Terminal Air Conditioners (PTACs)

 for  

your comfort conditioning requirements. PTAC units are 

thru-wall combination cooling and heating units, which 

provide an efficient, room-by-room source for comfort 

conditioning of your living environment. 

ICE AIR PTAC units are built to a high standard of 

quality and reliability, employing commercial grade 

components and heavy duty, galvanized sheet metal 

casings. With proper maintenance and usage, ICE AIR 

PTACs should provide many years of efficient, quiet 

and trouble-free comfort.

To enhance the use of your ICE AIR equipment, you 

will want to read and carefully follow all of the 

instructions contained in this Operating & Maintenance 

Manual. We recommend that you pay special 

attention to the Safety & Operation information 

section at the beginning of this Manual, and to the 

various safety advisories throughout this Manual.

Please retain this manual for your future reference. 

We suggest that you retain it with other important 

documents and product manuals. The information 

contained within this manual, unless noted herein, 

applies to all ICE AIR PTAC models. If your unit has 

optional features, they will be explained in a separate 

instruction sheet specific to that option.

On behalf of ICE AIR, and our network of distributors 

and dealers, we are happy to welcome you to our  

base of satisfied customers!

SAFTEY & OPERATION

FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE 

AIR PTAC UNIT, PLEASE READ THE FOLLOWING 

CONSUMER SAFETY AND OPERATING NOTES 

CAREFULLY BEFORE OPERATING YOUR EQUIPMENT!

• 

This unit MUST be serviced only by professionally 

trained, qualified technicians. Do NOT attempt to 

maintain or service this unit on your own – severe 

injury and death can occur from electric shock,  

moving parts, and other hazards. 

• 

Our ICE AIR units must each be wired on an  

individual, dedicated electrical circuit with  

the correct voltage and proper amperage  

(capacity) to match the unit nameplate  

requirements. 

• 

Each unit’s electric circuit must have a proper  

overcurrent protection device, employing an  

approved circuit breaker or fuse of the proper  

rating under NEMA and local building codes. 

• 

Every unit contains refrigerant within a sealed and 

pressurized refrigerant system. This system must 

not be opened or tampered with and any refrigera-

tion system repairs MUST be carried out by trained 

technicians. Refrigerant must be properly handled 

and recycled per EPA regulations and guidelines. 

Your ICE AIR unit must be properly installed and  

commissioned to operate correctly. Improper unit  

installation, adjustment or commissioning, and / or  

improper heating system installation and connection  

can lead to equipment malfunction and hazardous  

operating conditions, and may void your warranty.  

If you have any doubt about the proper installation  

of your PTAC unit, please contact your property  

manager at once to have a qualified technician  

inspect the equipment.  

LOCATION

MODEL #

SERIAL #

Living Room

Master Bedroom

Bedroom

Dining Room

We recommend that you record the following 

information about your ICE AIR PTAC products: 

Summary of Contents for RSAN

Page 1: ...Packaged Terminal Air Conditioner PTAC OPERATING MAINTENANCE MANUAL World Class Comfort Model RSAN ...

Page 2: ...Y OPERATION FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE AIR PTAC UNIT PLEASE READ THE FOLLOWING CONSUMER SAFETY AND OPERATING NOTES CAREFULLY BEFORE OPERATING YOUR EQUIPMENT This unit MUST be serviced only by professionally trained qualified technicians Do NOT attempt to maintain or service this unit on your own severe injury and death can occur from electric shock moving parts and other hazards Ou...

Page 3: ...ned or positioned so that the air discharge from the unit does not flow behind these window treatments Have the unit filter properly cleaned and serviced to prevent air blockage from dirt and dust within the filter media Proper installation and operating environment must be maintained Therefore Do not operate the unit in corrosive environments such as chemical plants refineries or salt spray areas...

Page 4: ...OPERATING MAINTENANCE MANUAL PACKAGED TERMINAL AIR CONDITIONER PTAC RSAN 4 RSAN EXPLODED VIEW ...

Page 5: ...5 OPERATING MAINTENANCE MANUAL PACKAGED TERMINAL AIR CONDITIONER PTAC RSAN DIMENSIONAL DRAWING ...

Page 6: ...ture set point is reached Fan Speed Press the FAN button to select high medium or low fan speed Operating Modes Press the MODE button to select between Cooling Heating and Fan modes 3 OPERATING MODES Cooling Mode Under cooling mode the user can select a specific fan speed and temperature set point Heating Mode Under heating mode the user can select a specific fan speed and temperature set point Fa...

Page 7: ...w Temperature Protection USER INTERFACE DESCRIPTION TROUBLESHOOTING E4 LOW REFRIGERANT CHARGE Low charge dirty filter or dirty evaporator coil E6 SYSTEM HIGH PRESSURE PROTECTION Condenser fan failure dirty condenser coil or capillary tube blockage E8 INDOOR COIL FREEZE PROTECTION Dirty filter dirty evaporator coil or fan motor failure E9 COMMUNICATION ERROR Faulty wiring from touchpad to board or ...

Page 8: ...ure Auto Mode To activate auto mode press the mode button until AUTO displays Press up down arrow keys to set desired heat temperature Wait 5 seconds for cool to appear Press up down arrow keys to set desired cool temperature The unit will automatically cycle between heat and cool modes if unit exceeds desired set points The temperature reading that is on constant display is the ambient room tempe...

Page 9: ...orary Program Override 1 When thermostat is ON the program set point can be temporarily overrode by pressing UP or DOWN OVERRIDE icon will turn on Press UP or Down to select the set point 2 In Heat mode Heat set point can be adjusted 3 In Cool mode Cool set point can be adjusted 4 In Auto mode Heat set point will be set first and press UP or DOWN to set the Heat set point Press Fan to confirm the ...

Page 10: ...hoses annually to ensure proper condensate drainage If any foreign matter build up in the drain pan is found clean the drain pan and drain hoses frequency of cleaning depends on the level of dirt and pollutants that may be present in the indoor environment Check and clean if necessary the unit evaporator coil annually Check unit line cord power connection for any fraying or deterioration of the pl...

Page 11: ...sive noise and vibration from this assembly it should be serviced by a qualified technician ROOMSIDE COMPONENT CLEANING EVAPORATOR COIL AND DRAIN PAN DRAIN HOSES IMPORTANT NOTE In addition to the air filter the roomside components can be cleaned without removing the PTAC chassis from the wall sleeve The power cord MUST be disconnected from the electrical outlet before carrying out any of the follo...

Page 12: ...UALIFIED TRAINED PERSONNEL ELECTRIC SHOCK HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING MOVING PARTS HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING UNIT MUST BE OPERATED WITH ALL CHASSIS SHEET METAL PARTS PROPERLY IN PLACE UNIT MUST BE OPERATED WITH ALL ENCLOSURE CABINET PARTS IN PLACE READ THIS ENTIRE OPERATIONS MANUAL BEFORE OPERATING THE UNIT DO NOT OPERATE UNIT W...

Reviews: