-18-
080417_Service manual Base, Wok- and Install-Line E
8
Adjustment of process parameters
The induction unit (excluding WOK-units) with new Cu sensors can be adjusted. This can be
done either by means of the short circuit plug Poti-LED art. nr. 94900096 or by PC/Laptop. In
addition, the pan detection and the performance can be adjusted by the hyperterminal program
of the PC/Laptop. Exact information to the use of the hyperterminal program is given in chapter
9 „IR interface“.
8.1
How to initialize CU sensors by the short circuit plug
If only the CU sensor is exchanged, the new CU sensor can be initialized by means of the short
circuit plug Poti-LED. For this, you will not need the PC/Laptop. The pan detection and the
performance will not have to be changed.
Prozedure of initialization:
-
The cooking area has to be devoid of any items
-
Surrounding temperature 25ºC (+/-3ºC)
-
Disconnect the induction unit from the mains supply
-
Put short circuit plug Poti-LED into the power print
-
Connect the induction unit to the mains supply
-
The CU sensors will now be initialized automatically
-
After successful initialization, the green LED on the CPU-print will illuminate.
-
In case the system will find an error during initialization, the red LED will illuminate
-
Disconnect the induction unit from the mains supply
-
Check the CU sensors at the plug by means of the Ohmmeter
-
Re-start the procedure of initialization
-
Disconnect the unit from the mains supply
-
Remove the short circuit plug Poti-LED