ICE /
10
OPERATOR MANUAL
WARNING: Before performing any
maintenance on the machine, be sure that
the power is turned off, or the batteries are
disconnected!
WARING: Repairs are to be completed
by Authorized service centers only. Any repairs
completed by unauthorized persons will avoid
the warrenty.
DAILY MAINTENANCE
1. Remove pad driver/ brush and clean with
approved cleaner.
2. Drain recovery and solution tanks completely
and rinse out with clean water. Visually check
the recovery tank for debris and clean out as
necessary.
3.
Raise the squeegee assembly off floor and wipe
it down with a damp towel. Be sure to store the
squeegee in the up position.
4.
Remove the float shut-off assembly and rinse it
out with clean water.
5. Clean machine with an approved cleaner and a
damp towel.
6. Recharge the batteries.
7. Check the condition of the squeegee blade
wiping edge, rotate blade if worn.
MONTHLY MAINTENANCE
1. Clean the battery tops to prevent corrosion.
2. Check for loose battery cable connections.
3. Inspect and clean the recovery tank cover seal.
Replace it if damaged.
4. Lubricate all grease points and pivot points with
silicon spray and approved grease.
5. Check the machine for loose nuts and bolts.
6. Check the machine for leaks.
ORBITAL HEAD MAINTENANCE
For Orbital head, you should have checked the
eight isolators located in the Orbital head every 300
hours.
1.
Using a flashlight, do a visual inspection of the
isolators by looking through the opening in the
Orbital head and checking for wear or damage
to four isolators in the front and four in the rear
of the Orbital head. The locations of the isolators
are show below.
2. If any of the eight isolators show signs of wear,
degradation or damage, contact your local
distributor to replace all eight isolators.
MACHINE STORAGE
1. Always store the machine indoors.
2. Always store the machine in a dry area.
3. Always store the machine in its upright position.
4. Always store the machine with the pad driver/
brush raised off the floor.
5. Always store the machine with the squeegee
assembly raised off the floor.
6. If storing in an area which may reach freezing
temperatures, be sure to drain all fluids from the
machine prior to storage. Any damage caused by
freezing temperatures will not be covered by the
warranty.
7. Drain the recovery tank.
8.
Drain the solution tank of all fluid.
PREVENTATIVE MAINTENANCE
Summary of Contents for i-SYNEGY i20NBTL+
Page 14: ...14 ICE i20NBTL i24BTL PARTS LIST RECOVERY TANK GROUP ...
Page 16: ...ICE i20NBTL i24BTL 16 PARTS LIST VACUUM FAN GROUP 12 ...
Page 18: ...ICE i20NBTL i24BTL 18 PARTS LIST SOLUTION TANK GROUP ...
Page 21: ...21 ICE i20NBTL i24BTL PARTS LIST CONTROL CONSOLE GROUP i20NBTL i24BTL ...
Page 25: ...25 ICE i20NBTL i24BTL PARTS LIST FRAME TRANSAXLE GROUP i20NBTL i24BTL ...
Page 28: ...ICE i20NBTL i24BTL 28 PARTS LIST SCRUB HEAD GROUP i20NBTL ...
Page 30: ...30 ICE i20NBTL i24BTL PARTS LIST SCRUB HEAD GROUP i24BTL ...
Page 32: ...ICE i20NBTL i24BTL 32 PARTS LIST SCRUB HEAD LIFT GROUP i20NBTL ...
Page 34: ...34 ICE i20NBTL i24BTL PARTS LIST SCRUB HEAD LIFT GROUP i24BTL ...
Page 36: ...ICE i20NBTL i24BTL 36 PARTS LIST SQUEEGEE GROUP ...
Page 38: ...ICE i20NBTL i24BTL 38 PARTS LIST SOLUTION GROUP ...