ELEVATION SERIES CIM CUBERS
SEQUENCE OF OPERATIONS
15
CONTROL BOARD - PRE-CHILL
The Compressor and Fan(s)/Liquid Line Solenoid (R1 and R2 LED’s on Board illuminated) are energized
and unit is now in a Pre‐Chill for 30 seconds bringing the Evaporator temperature down. Both Curtain
Switch LED’s are on showing closed curtain(s). Even though (R1) is energized the Fan Motor will only
come on once the Fan Cycle Switch closes at 250 psi of head pressure.