SEQUENCE OF OPERATIONS
24
CONTROL BOARD - RETURN TO FREEZE
As the ice slab falls from the Evaporator, the Curtain(s) is pushed out and the contacts of the Curtain
Switch(s) open and close, terminating the Harvest Cycle. With a closed Curtain and Bin Thermostat (if
added), the unit will restart the Freeze Cycle. The Compressor (R2) and Fan(s) (R1) will continue opera‐
tion as the Water Inlet Valve (R4) is energized to fill the Sump until the High Water Float opens.
BROWN
BLUE
VIOLET
BLACK
RED
TAN
PINK
YELLOW
= Illuminated LED
WHITE
WHITE
BLUE w/ WHITE
BLUE w/ RED
BLUE
12V DC Switches
Line Voltage
Components
R1
R2
R3
R4
R5
R6