ELEVATION SERIES CIM CUBERS
EVAPORATOR REPLACEMENT
54
The new evaporator comes with two new side wall pieces. For a single evaporator unit you will only use
the exterior right side wall that comes in the kit to replace the existing right side wall. This will allow the
new evaporator to be installed without interfering with the plastics. It has cut outs to allow for the new
tubing routing. For reference, see the image labeled “Exterior Right Wall” in the dual evaporator replace‐
ment section for correct part identification.
Remove the right hand side
wall and discard. You will
replace it with a new one
that is provided in the kit.
Summary of Contents for CIM Series
Page 31: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 29 INITIAL HARVEST CYCLE AT START UP ...
Page 32: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 30 TRANSITION FROM HARVEST TO FREEZE ...
Page 33: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 31 BIN FULL CURTAIN OR STAT ...
Page 35: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 33 DIAGNOSTICS IN HARVEST CYCLE ...
Page 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 34 Button Functions ...