ELEVATION SERIES CIM CUBERS
REMOTE CONDENSER GUIDELINES
5
Route the refrigerant lines through the roof opening. Follow straight line routing whenever possible. Any
excess tubing MUST remain inside the building. Spiral the excess length of pre-charged tubing inside the
building. Use a horizontal spiral to avoid any traps in the lines.
Have the roofing contractor seal the holes in the roof per local codes.
CAUTION: The couplings on the sets of pre-charged lines are self sealing when installed properly. Carefully
follow the instructions in the Remote Condenser manual.
The following remote ice makers incorporate the Mixing Valve in the Condenser. This configuration
allows up to a 100 foot calculated remote line set run. Reference the diagram on the next page to calculate
the maximum 100 ft. line set run. Maximum
actual line set run
is limited to 75ft.
Verify the CIM machine is compatible with the remote condenser.
For more information contact your Ice-O-Matic distributor.
CIM Machine Model Number
Remote Condenser Model Number
CIM0530R
VRC1001B/RCA1001
CIM0535R
VRC1061B/RCA1061
CIM0636R
VRC1061B/RCA1061
CIM0825R/0826R/0835R/0836R/0837R
VRC2061B/RCA2061
CIM1125R/1126R/1135R/1136R/1137R
VRC2061B/RCA2061
CIM1446R/1447R
VRC2661/RCA3061
CIM1545R/1845R
VRC2661/RCA3061
CIM2046R/2047R
VRC5061B/RCA3561
Summary of Contents for CIM2046
Page 31: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 29 INITIAL HARVEST CYCLE AT START UP...
Page 32: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 30 TRANSITION FROM HARVEST TO FREEZE...
Page 33: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 31 BIN FULL CURTAIN OR STAT...
Page 35: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 33 DIAGNOSTICS IN HARVEST CYCLE...
Page 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 34 Button Functions...