Component Replacement ICEU060
Page 15
Bin Thermostat
1. Unplug the icemaker to disconnect electrical power.
2. Remove screws and cabinet front panel.
3. Remove screws and the control box cover, disconnect electrical wires from the bin thermostat control.
4. Dismount the bin thermostat from the control box.
5. Remove the rear panel.
6. Pull the bin thermostat capillary line from the tube in the ice storage bin. Remove complete control from
ice machine.
7. Replace with a new control in reverse order of removal.
Cube Size Control
1. Unplug the icemaker to disconnect electrical power.
2. Remove screws and cabinet top, front and rear panels.
3. Pull knob from the cube size control shaft. Remove screws and control box cover to gain access to the
cube size control body. Remove screws and dismount the cube size control from the control box.
Disconnect the electrical wires from the cube size control.
4. At the top of the machine, unclip the cube size thermostat tube holder from the evaporator (retain the
clips and tube assembly). Pull the cube size control capillary tube from the tube holder, and remove the
complete cube size control from the icemaker.
5. Insert new cube size control capillary tube into the tube holder, (insure that the end caps are in place).
6. Reverse the removal procedures to reinstall the cube size control. Adjust as necessary.
Refrigeration System
Any time the refrigeration system is opened, the drier must be replaced, the system evacuated and the
exact charge measured into the system. Any other procedure is incorrect and will result in substandard
performance.