background image

Component Replacement                                                                     ICEU060

Page 15

Bin Thermostat

1.  Unplug the icemaker to disconnect electrical power.
2.  Remove screws and cabinet front panel.
3.  Remove screws and the control box cover, disconnect electrical wires from the bin thermostat control.
4.  Dismount the bin thermostat from the control box.
5.  Remove the rear panel.
6.  Pull the bin thermostat capillary line from the tube in the ice storage bin.  Remove complete control from

ice machine.

7.  Replace with a new control in reverse order of removal.

Cube Size Control

1.  Unplug the icemaker to disconnect electrical power.
2.  Remove screws and cabinet top, front and rear panels.
3.  Pull knob from the cube size control shaft.  Remove screws and control box cover to gain access to the

cube size control body.  Remove screws and dismount the cube size control from the control box.
Disconnect the electrical wires from the cube size control.

4.  At the top of the machine, unclip the cube size thermostat tube holder from the evaporator (retain the

clips and tube assembly).  Pull the cube size control capillary tube from the tube holder, and remove the
complete cube size control from the icemaker.

5.  Insert new cube size control capillary tube into the tube holder, (insure that the end caps are in place).
6.  Reverse the removal procedures to reinstall the cube size control.  Adjust as necessary.

Refrigeration System

Any time the refrigeration system is opened, the drier must be replaced, the system evacuated and the
exact charge measured into the system.  Any other procedure is incorrect and will result in substandard
performance. 

Summary of Contents for ICEU060

Page 1: ...Mile High Equipment 11100 East 45th Ave Denver Colorado 80239 Part Number 9081291 01 Print Date 11 01 MODEL ICEU060 ICE UNDERCOUNTER SERIES CUBERS SERVICE AND INSTALLATION MANUAL...

Page 2: ...Works Water System Page 9 How It Works Refrigeration Page 10 11 Operation And Adjustment Page 12 Sanitizing And Cleaning Page 13 Service Diagnosis Page 14 Component Replacement Page 15 16 Wiring Diag...

Page 3: ...or installations Machine requires voltage indicated on rating nameplate Failures caused by improper voltage are not considered factory defects Extended periods of operation at temperatures exceeding l...

Page 4: ...lity connections Allow enough space for the machine to be pulled out from its installed location Do not build a floor in front of the machine that would prevent its removal Air Circulation The front p...

Page 5: ...un is recommended Install the drains per local code A vent is recommended on the highest point of the drain tube and the drain tubing must be rigid pipe DO NOT use flexible tubing Electrical 1 Locate...

Page 6: ...cuit 5 Is the water supply line shut off valve installed and is the water turned on 6 Have the bin interior and cabinet exterior been wiped clean 7 Are all internal components in place including spray...

Page 7: ...uns this is normal 9 After about 20 minutes the machine will begin to release ice This is called the harvest cycle Observe the first cube harvest a Check the size of the ice cubes Note The normal size...

Page 8: ...tat control body is located in front of the control box just beside the cube size control The thermostat sensing tube is located in the ice storage bin on the left side wall and will automatically shu...

Page 9: ...Component Location ICEU060 Page 8...

Page 10: ...ns and hot refrigerant gas is discharged into the evaporator The inlet opens and a fresh supply of water flows to the top of the evaporator and then drains into the reservoir The ice cubes have been r...

Page 11: ...the condenser The refrigerant then condenses into a high pressure liquid From the condenser the liquid refrigerant flows through the liquid line and the liquid line filter drier After the filter drie...

Page 12: ...strainer outlet is connected to two tubes one which leads to a hot gas valve solenoid When this valve opens the refrigerant gas follows the path of least resistance and flows through the tubing from t...

Page 13: ...llustration at the right 1 Remove the front panel locate knob 2 To increase the cube size turn knob 1 8 turn clockwise To decrease the cube size turn the knob 1 8 turn counter clockwise 3 Observe the...

Page 14: ...ce produced during cleaning and to clean out the drain Wipe the interior of the bin with mild soap and hot water rinse with cold water To sanitize prepare ounce of approved EPA FDA sodium hypochloride...

Page 15: ...jets Some cloudy Shortage of water Check water supply Cubes too large Cube size control adjusted Check and adjust for proper operation improperly Decreased ice capacity Inefficient compressor Replace...

Page 16: ...rews and control box cover to gain access to the cube size control body Remove screws and dismount the cube size control from the control box Disconnect the electrical wires from the cube size control...

Page 17: ...er valve 4 Disconnect electrical wires from the inlet water valve 5 Disconnect water lines to and from the water valve 6 Remove the valve from the icemaker 7 Reverse removal procedure to replace Water...

Page 18: ...Component Layout ICEU060 Page 17...

Page 19: ...Wiring Diagram ICEU060 Page 18...