background image

Initial Start Up                                                                                        ICEU060

Page 6

1.  Open the water supply valve.
2.  Move electrical breaker or switch to the 

ON

 position.

3.  Remove the front panel.
4.  Check the cube size control shaft, it should be in a preset position.  If not, rotate the control shaft

clockwise until the unit comes on.  

      Note:  Cube size adjustments may be required.  Start with the shaft in the “mid” position

.

5.  The machine will go through a “dry cycle”; this will take about 10 minutes.  The water fill and harvest

cycle will begin.

6.  Observe the water fill cycle:

$

   The water inlet valve opens.

$

   Incoming water flows from the water valve through the tubing to the top of the icemaker.

$

  Water flows around the inverted ice cube cups and drains through holes into the reservoir.

$

  The reservoir begins to fill up with water.

$

  Water continues to enter the machine and overflows a standpipe in the reservoir and down the

drain.  This will take about 3 ½ minutes.  After that, the freeze cycle will begin.

7.  Check the operation of the freezing cycle:

a

  Compressor is running.

a

  Water pump is spraying water through the spray nozzles.

a

  Ice making begins, ice begins to form in the cube molds.

8.  Check that the plastic curtain assembly hangs down evenly in the opening and that no large streams of

water are passing through.

      Note: Some water will drip from the reservoir as the machine runs, this is normal.
9.  After about 20 minutes, the machine will begin to release ice.  This is called the harvest cycle. 

$

  Observe the first cube harvest:

a

 

 Check the size of the ice cubes.

      Note: The normal size of the ice cube has a ¼ inch depression in the wide end.

If the cubes are not filled out, adjust the machine to make larger ice cubes by turning the cube size
control shaft clockwise. 
If the cubes are overfilled, adjust the machine to make smaller ice cubes by turning the cube size
control counter-clockwise.
In both cases, the next cycle of cubes harvested must be observed, and further corrections may be
needed.
If the ice cubes are cloudy, an extreme water condition may exist.  Confirm that they are cloudy by
placing them in a glass of cold water.  If, in the water, they remain cloudy, you may want to have the
water tested by a water treatment specialist.  If the cubes are cloudy only on the bottom or in the
center of the cube, the machine may be running out of water before the end of the freeze cycle.

10.  Test the bin full shut off.  To test this, hold some ice on the bin thermostat bracket (the stainless steel

tube in the left-hand side of the ice storage bin).  The icemaker should stop within a few minutes of
having ice on that tube.

11.  Fill out the Warranty Registration and Customer Evaluation form, and mail both to Ice-O-Matic.
12.  Make sure the user understands the operation and maintenance requirements for the icemaker.  Leave

the service manual and name of the local Ice-O-Matic service agency with the user.   

Summary of Contents for ICEU060

Page 1: ...Mile High Equipment 11100 East 45th Ave Denver Colorado 80239 Part Number 9081291 01 Print Date 11 01 MODEL ICEU060 ICE UNDERCOUNTER SERIES CUBERS SERVICE AND INSTALLATION MANUAL...

Page 2: ...Works Water System Page 9 How It Works Refrigeration Page 10 11 Operation And Adjustment Page 12 Sanitizing And Cleaning Page 13 Service Diagnosis Page 14 Component Replacement Page 15 16 Wiring Diag...

Page 3: ...or installations Machine requires voltage indicated on rating nameplate Failures caused by improper voltage are not considered factory defects Extended periods of operation at temperatures exceeding l...

Page 4: ...lity connections Allow enough space for the machine to be pulled out from its installed location Do not build a floor in front of the machine that would prevent its removal Air Circulation The front p...

Page 5: ...un is recommended Install the drains per local code A vent is recommended on the highest point of the drain tube and the drain tubing must be rigid pipe DO NOT use flexible tubing Electrical 1 Locate...

Page 6: ...cuit 5 Is the water supply line shut off valve installed and is the water turned on 6 Have the bin interior and cabinet exterior been wiped clean 7 Are all internal components in place including spray...

Page 7: ...uns this is normal 9 After about 20 minutes the machine will begin to release ice This is called the harvest cycle Observe the first cube harvest a Check the size of the ice cubes Note The normal size...

Page 8: ...tat control body is located in front of the control box just beside the cube size control The thermostat sensing tube is located in the ice storage bin on the left side wall and will automatically shu...

Page 9: ...Component Location ICEU060 Page 8...

Page 10: ...ns and hot refrigerant gas is discharged into the evaporator The inlet opens and a fresh supply of water flows to the top of the evaporator and then drains into the reservoir The ice cubes have been r...

Page 11: ...the condenser The refrigerant then condenses into a high pressure liquid From the condenser the liquid refrigerant flows through the liquid line and the liquid line filter drier After the filter drie...

Page 12: ...strainer outlet is connected to two tubes one which leads to a hot gas valve solenoid When this valve opens the refrigerant gas follows the path of least resistance and flows through the tubing from t...

Page 13: ...llustration at the right 1 Remove the front panel locate knob 2 To increase the cube size turn knob 1 8 turn clockwise To decrease the cube size turn the knob 1 8 turn counter clockwise 3 Observe the...

Page 14: ...ce produced during cleaning and to clean out the drain Wipe the interior of the bin with mild soap and hot water rinse with cold water To sanitize prepare ounce of approved EPA FDA sodium hypochloride...

Page 15: ...jets Some cloudy Shortage of water Check water supply Cubes too large Cube size control adjusted Check and adjust for proper operation improperly Decreased ice capacity Inefficient compressor Replace...

Page 16: ...rews and control box cover to gain access to the cube size control body Remove screws and dismount the cube size control from the control box Disconnect the electrical wires from the cube size control...

Page 17: ...er valve 4 Disconnect electrical wires from the inlet water valve 5 Disconnect water lines to and from the water valve 6 Remove the valve from the icemaker 7 Reverse removal procedure to replace Water...

Page 18: ...Component Layout ICEU060 Page 17...

Page 19: ...Wiring Diagram ICEU060 Page 18...

Reviews: