How It Works                                                                                          ICEU060

Page 7

Component Description

Cube Size Control

The Cube size control is located in the front of the control box, behind the front panel.  The sensing capillary
tube of the cube size control is routed out of the control box into its bulb holder on the evaporator coil.  It is a
reverse acting temperature control with double throw contacts.  Turning its knob all the way
counterclockwise also shuts off the icemaker.

Compressor Toggle Switch

The compressor toggle switch is located on the side of the control box.  When moved to the 

ON

 position, it

makes a circuit to the compressor.  When moved to the 

OFF

 position, the other components will still

operate.

Water Pump

The water pump operates during the freezing cycle only, pumping water through the spray nozzles into the
inverted spray cups.

Inlet Water Solenoid Valve

The water solenoid valve, located in the back panel of the unit, is energized only during the harvest or
cleaning cycles.  When energized, it allows a metered amount of water to flow into the machine (.21 GPM).
This water flows to the top of the evaporator and then down into the reservoir.

Bin Thermostat Control

The bin thermostat control body is located in front of the control box just beside the cube size control.  The
thermostat sensing tube is located in the ice storage bin on the left side wall and will automatically shut the
icemaker off when the bin is full and restart when ice is removed.  Factory settings are 36º F cut out and 39º
F cut in.  It can be adjusted by turning the adjustment screw visible through the control box cover.

Hot Gas Valve Assembly 

The hot gas valve assembly is comprised of two components, the valve body and the coil.  These
components are located on the discharge line of the compressor and are activated by the cube size control
(harvest cycle).  When the coil of the hot gas valve is energized, it magnetically lifts the plunger in the hot
gas valve body.  This allows hot refrigerant gas to by-pass the condenser and go directly to the evaporator.

Spray Platform and Chute

The spray system used on this unit is of the stationary type.  The water is forced by the water pump into the
platform chamber and sprayed into the inverted cup molds through a set of six spray nozzles.

Fan Motor

The fan motor is electrically connected through the cube size control and runs only during the freeze cycle.

Hermetic Motor Compressor

The compressor is a vapor pump, forcing refrigerant gas throughout the refrigeration system.

Reference Page 8 for Component Location

.

Summary of Contents for ICEU060

Page 1: ...Mile High Equipment 11100 East 45th Ave Denver Colorado 80239 Part Number 9081291 01 Print Date 11 01 MODEL ICEU060 ICE UNDERCOUNTER SERIES CUBERS SERVICE AND INSTALLATION MANUAL...

Page 2: ...Works Water System Page 9 How It Works Refrigeration Page 10 11 Operation And Adjustment Page 12 Sanitizing And Cleaning Page 13 Service Diagnosis Page 14 Component Replacement Page 15 16 Wiring Diag...

Page 3: ...or installations Machine requires voltage indicated on rating nameplate Failures caused by improper voltage are not considered factory defects Extended periods of operation at temperatures exceeding l...

Page 4: ...lity connections Allow enough space for the machine to be pulled out from its installed location Do not build a floor in front of the machine that would prevent its removal Air Circulation The front p...

Page 5: ...un is recommended Install the drains per local code A vent is recommended on the highest point of the drain tube and the drain tubing must be rigid pipe DO NOT use flexible tubing Electrical 1 Locate...

Page 6: ...cuit 5 Is the water supply line shut off valve installed and is the water turned on 6 Have the bin interior and cabinet exterior been wiped clean 7 Are all internal components in place including spray...

Page 7: ...uns this is normal 9 After about 20 minutes the machine will begin to release ice This is called the harvest cycle Observe the first cube harvest a Check the size of the ice cubes Note The normal size...

Page 8: ...tat control body is located in front of the control box just beside the cube size control The thermostat sensing tube is located in the ice storage bin on the left side wall and will automatically shu...

Page 9: ...Component Location ICEU060 Page 8...

Page 10: ...ns and hot refrigerant gas is discharged into the evaporator The inlet opens and a fresh supply of water flows to the top of the evaporator and then drains into the reservoir The ice cubes have been r...

Page 11: ...the condenser The refrigerant then condenses into a high pressure liquid From the condenser the liquid refrigerant flows through the liquid line and the liquid line filter drier After the filter drie...

Page 12: ...strainer outlet is connected to two tubes one which leads to a hot gas valve solenoid When this valve opens the refrigerant gas follows the path of least resistance and flows through the tubing from t...

Page 13: ...llustration at the right 1 Remove the front panel locate knob 2 To increase the cube size turn knob 1 8 turn clockwise To decrease the cube size turn the knob 1 8 turn counter clockwise 3 Observe the...

Page 14: ...ce produced during cleaning and to clean out the drain Wipe the interior of the bin with mild soap and hot water rinse with cold water To sanitize prepare ounce of approved EPA FDA sodium hypochloride...

Page 15: ...jets Some cloudy Shortage of water Check water supply Cubes too large Cube size control adjusted Check and adjust for proper operation improperly Decreased ice capacity Inefficient compressor Replace...

Page 16: ...rews and control box cover to gain access to the cube size control body Remove screws and dismount the cube size control from the control box Disconnect the electrical wires from the cube size control...

Page 17: ...er valve 4 Disconnect electrical wires from the inlet water valve 5 Disconnect water lines to and from the water valve 6 Remove the valve from the icemaker 7 Reverse removal procedure to replace Water...

Page 18: ...Component Layout ICEU060 Page 17...

Page 19: ...Wiring Diagram ICEU060 Page 18...

Reviews: