32
PREP
ARING THE
APPLIANCE
• Using the optional system for automatic clean water top-up (5)
(
Fig.5
). This system has a float for avoiding any overflow.
5. Fill with clean water, at a temperature not higher than 50°C and
not lower than 10°C. The amount inside the tank can be seen by
means of the level tube (6) (
Fig.6
) on the front left of the seat.
DETERGENT SOLUTION
After filling the solution tank with clean water add the liquid
detergent to the tank in the concentration and manner indicated on
the detergent manufacturer's label. To prevent the formation of an
excessive amount of foam that could damage the vacuum motor, use
the minimum percentage of detergent required.
ATTENTION:
protective gloves should always be worn before
handling detergents or acidic or alkaline solutions, to avoid
serious injury to the hands.
ATTENTION:
always use detergents whose manufacturer's
label indicates their suitability for scrubbing machines. Do not
use acid or alkaline products or solvents without this
indication.
ATTENTION:
acid or alkaline maintenance detergent tank be
used with pH values between 4 and 10 and that do not
contain: oxidising agents, chlorine or bromine, formaldehyde,
mineral solvents. The detergents used must be suitable for
use with scrubbing machines.
ATTENTION:
always use low-foam detergent. To avoid the
production of foam, put a minimum quantity of antifoam liquid
in the recovery tank before starting to clean. Do not use pure
acids.
ATTENTION:
to make it easier to measure the detergent on
the cap/measuring device, there are two notches indicating
the two main detergent percentage quantities that can be
used.
6
5
5