SERVICE MANUAL
13
4.- Connect the machine to the power supply.
5.- For under counter models: push the switch on the machine front side. For modular models:
push the switch found on the back of the machine and then set the ice-wash switch to the position
ice.
6.- Verify that there are no vibrations or frictions on the elements.
7.- Verify that the water fall to the evaporator is occurring uniformly and all ice cubes are properly
watered.
8.- Close door (for under counter models) / Replace the front panel in its place (for modular
models).
9.- For modular models: Verify the ice slab with the pictures below. In case the thickness sensor
needs to be regulated, rotate the thickness adjustment screw CW to increase bridge thickness.
Rotate CCW to decrease bridge thickness. For under counter models adjust the cycle time dip
switches (see point 4.1).
Damages due to the lack of maintenance and cleaning operations are not included on the
warranty.
Thickness
sensor