SERVICE MANUAL
23
t9
Water inlet valve e/w timeout
180”
t10
Production maximum timeout
3600’’
t11
Pump start-up delay time
30”
t12
Draining time at cleaning cycle
60”
t13
Retry time due to water inlet valve e/w timeout
3600’’
t14
Upper unit change
60’’
t15
Maximum time to reset due to security pressure switch
600’’
5.2.-MS CONTROL BOARD
PCB connections
Outputs
C
compressor
B
Water pump
EW
Water inlet valve
GC
Hot gas valve.
EP
Drain valve
SL
Free
Inputs
ICE
Ice position switch
WASH
Wash position switch
P
Safety pressure switch / NC contact
MC
Curtain micro relay contact NC
EL
Free
ESP
Thickness detection sensor
NW
Water level in reservoir
CO1
Connector for staking machines