Watchdog timer
•
Oscillator watchdog
•
Timer0
•
Timer1
•
SSC
When the jumper top is on, the
BREAK
mode is selected. In this case, only some of the internal
peripherals are stopped. This includes the following controller peripherals.
•
Interrupts
•
Watchdog timer
•
Oscillator timer
Timer0, Timer1, and SSC are not stopped in this mode.
In
STOP
and
BREAK
, all of the internal peripherals start working from the same point they
stopped before the break as soon as the user program starts running again when you press the
GO
or
STEP
buttons. When changing this jumper, the new
STOP/BREAK
mode takes effect
after the next
RESET
sequence. The default setup of the jumper is
STOP
mode selection (jumper
top out).
Note:
It is recommended to work in
STOP
mode only. The break mode needs to be se-
lected only if your application has limitations that do not allow the timers to be
stopped in monitor mode.
XL0..XL7: Port Select Jumpers
These eight 3-pin jumpers select the signals that are routed to the trace board and are shown in
the trace window under the header P1. For any jumper in this group the jumper top position pin
2–pin 3 means that the corresponding pin of the recreated Port0 is traced. Pin 1 of each jumper
is left free and can be connected to any signal on the target or port headers on the pod. For ex-
ample setting XL4 in position 2–3 means that pin P0.4 is traced. If pin XL4.1, for
example, is connected to a signal P4.3 on the target, you can choose between tracing signal
P0.4 or P4.3 by moving the jumper between positions 2–3 and 1–2.
XH0..XH7: Port Select Jumpers
This group of jumpers is similar to XL0..XL7 except pin 3 of each jumper is connected to the
recreated Port2 and pin 1 is left free.