background image

E N G L IS H

 

 

 

3. Stop 

 

When the “Start/Stop” button is switched off, water pump and solenoid valve stop working immediately, and the gear box stops 
working too after a 3-minute delay so as to remove the ice left on the interior of the vaporization cylinder. Now the pneumatic 
switch shall not be turned off before being delayed for 3 minutes. 

 

Stoppage due to alarm 

Stoppage due to ice full level alarm (normal stop): 
When microprocessor of computer’s main board detects full level of ice storage tank, the programmed process of ice full level 
shall be implemented: water pump and solenoid valves stop first, and then gear box motor stops after 3-minute delay and ice full 
level indicator turns on at the same time. Now the system is in stand-by mode. After ice is discharged, the system automatically 
restore to normal operating status: gear box motor, water pump and solenoid valve will be started in sequence. 

 

IMPORTANT! 

ADVISE THE FINAL USER ON MAINTENANCE PROCEDURES WHICH 

ARE NOT INCLUDED IN WARRANTY, 

AS WELL AS 

THOSE BREAKDOWNS CAUSED BY NEGLECT OF PROPER MAINTENANCE PROCEDURES. 

 

 

MAINTENANCE AND CLEANING INSTRUCTIONS 

 

IMPORTANT! 

 

**Maintenance and cleaning procedures as well as problems derived from failing to carry them out are not covered by the 
warranty. 
Proper maintenance is essential to obtain favourable ice quality and optimum functioning of unit. 
Frequency depends on water quality and characteristics of room where unit is installed. 

** Maintenance/cleaning procedures should take place at least once every six months. If concentration of air pollutants is high, 

complete procedures on a monthly basis. 
 

1.  Switch off the machine, turn off the water. 

 

2.  Remove the evaporator cover to clean all metal components of the evaporator: water distributor, 

main shaft, cutter, cutter supports, lower cross, etc...as described in point 3. 

 

3.  Cleaning of all metal parts. Dirt and surface rust stains must be completely removed by rubbing with 

a non-abrasive cloth or similar, which does not scratch or damage the metal surfaces of the walls 
and supports using soapy water, phosphoric acid in a proportion between 20 and 50% or a specific 
product for steel. 

 

Dirt and surface rust must be removed with sufficient frequency when they appear, preventing them 
from remaining on the metal components for long periods of time.  

 

In the case of saline environments, the frequency of cleaning should be increased, and 
maintenance should be carried out as soon as surface stains are observed and removed as soon as 
possible. 

 

IMPORTANT: In cases of prolonged lack of cleaning, dirt and surface rust in humid 
conditions could attack and damage the steel of the machine components, so it is 
recommended to remove them as soon as they appear. Both the cleaning and the possible 
deterioration of the machine due to lack of cleaning are not included in the machine 
manufacturer's guarantee. 

 

4.  Cleaning the water collection channel. Check the condition of the water channel, clean the water 

collection channel and the return inlet to the bucket. Carry out the same procedure as in point 3, 
using a plastic bristle brush in the event of stains, accumulation of dirt or surface rust, applying 
soapy water. 

 

5.  Rinse the unit with water. Open the drain valve to completely empty the basin (on models that have 

one, if not, remove the water by external means). If there are sediments, remove them with a cloth. 
Close it again.  

 

6.  Switch on the machine. Start making ice and remove the ice produced in the first 5 minutes. 

Summary of Contents for SCL 400

Page 1: ...Technical Manual Manual T cnico...

Page 2: ...L 15T SC 15TN TABLE OF CONTENTS 1 INTRODUCTION 4 Warnings 4 Overview 5 Wiring Diagram 6 2 SPECIFICATIONS 8 Production Tables 11 3 DELIVERY AND UNPACKING 13 4 INSTALLATION 13 Recommended Placement of U...

Page 3: ...RE cleaning or maintaining the equipment Do not attempt to install service or modify this machine Improper use by other than specially trained technicians is extremely dangerous and may result in a fi...

Page 4: ...machines The ice machine system is of vertical internal ice scraping type The machine is equipped with an electric box with different protections and status lights namely 1 Ice level 2 Water pressure...

Page 5: ...E N G L IS H 3 Wiring Diagram COMPACT SCL SC...

Page 6: ...E N G L IS H COMPACT SCL SC with V f driver...

Page 7: ...SCL SPLIT SC SPLIT E N G L IS H...

Page 8: ...E N G L IS H SCL SPLIT SC SPLIT with V f driver...

Page 9: ...ION 0 4T 0 6T REFRIGERANT R449A POWER 1425W 2350W AMBIENT TEMPERATURE 25oC WATER TEMPERATURE 16oC WATER CONSUMPTION 17 L H 25 L H WATER INLET 3 4 GAS DRAIN 21mm ELECTRICAL REQUIREMENTS 380 50Hz 3N DIM...

Page 10: ...ion measurement and size of ice outlet of 1 3 ton ice maker PIPE CONNECTION PIPE CONNECTION DIMENSIONS OF ICE OUTLE MODEL A B C D E L W H SCL 1T SC 1TN 150 750 198 490 310 1050 850 870 480 SCL 2T SC 2...

Page 11: ...1850 1150 1000 1 250 1050 1 50 775 575 1600 1500 650 150 900 SCL 15T SC 15TN 2510 1800 1230 1 285 1700 1 50 900 900 2200 1950 960 250 1580 SCL 20T SC 20TN 2510 1800 1230 1 285 1700 1 50 900 900 2400...

Page 12: ...0 25 640 610 600 580 550 530 510 30 560 540 530 500 480 460 450 38 500 490 480 460 440 430 400 SCL 1T SC 1TN Ta Tw 5 10 15 20 26 32 38 10 1200 1100 1050 1000 900 830 750 25 1100 1000 950 900 850 780 6...

Page 13: ...1580 SCL 5T SC 5TN Ta Tw 5 10 15 20 26 32 38 10 5600 5500 5200 5000 4600 4200 3800 25 5400 5300 5000 4600 4300 3900 3400 30 4900 4600 4300 3900 3400 3000 2900 38 4400 4300 4000 3600 3200 2900 2500 SC...

Page 14: ...N REACH OF CHILDREN INSTALLATION 1 Recommended Placement of Unit Sockets and wiring must comply with local standards for electrical appliances and requirements set forth on the rating plate of the mac...

Page 15: ...rating plate 2 Starting up Open feed water valve and fill up the water tank and the floating valve automatically closes when water level reaches the spillover port During trial operation pneumatic mai...

Page 16: ...urn off the water 2 Remove the evaporator cover to clean all metal components of the evaporator water distributor main shaft cutter cutter supports lower cross etc as described in point 3 3 Cleaning o...

Page 17: ...or low water level alarm Low water pressure Clean or replace filters Ice production decreases Regulation valve partially blocked or improperly adjusted Adjust or replace float valve Low water level of...

Page 18: ......

Page 19: ......

Reviews: