ICE TECH SS / SP Technical Service
Manual
22
MAINTENANCE TABLE:
PROCEDURE
MONTHLY
QUARTERLY
HALF
YEARLY
YEARLY BIENNIAL DURATION
Air condenser
cleaning
30 minutes
Water condenser
cleaning
90 minutes
Inyectors cleaning
30 minutes
Fabrication head
filter cleaning
30 minutes
Water circuit
cleaning
45 minutes
Sanitary cleaning
30 minutes
Water filter
cleaning/replacement
30 minutes
Gearbox cleaning
--
General unit cleaning
--
Depending on room characteristics
Depending on water quality
Carried out by owner
Essential
Maintenance and cleaning procedures as well as problems derived from failing to carry them out
ARE NOT COVERED BY THE WARRANTY. Service personnel will invoice you for travel
expenses, time invested and materials required for maintenance and cleaning of unit.
8. MAINTENANCE AND CLEANING PROCEDURES
WARNING: Unit should always be disconnected during maintenance/cleaning procedures.
Water Condenser
1) Disconnect machine.
2) Close water faucet.
3) Disconnect water entry/exit from condenser.