MAIN FUSE
Function
The control board fuse stops ice machine operation if
electrical components fail causing high amp draw.
Specifications
• IC-0170/IU-0170/IC-0220/IU-0220 - 250 Volt, 5 amp
• WU-0100 - 250 Volt 1 amp
n
Warning
High (line) voltage is applied to the control board at
all times. Removing the control board fuse or pressing
the power button will not remove the power supplied
to the control board.
Check Procedure
1. If the power light is lit on the front of the machine,
the fuse is good.
n
Warning
Disconnect electrical power to the entire ice machine
before proceeding.
2. Remove the fuse. Check for continuity across the fuse
with an ohmmeter.
Reading
Result
Open (OL)
Replace fuse
Closed (O)
Fuse is good