background image

27

9. Error Type

Display

Error type

Causes

Action

Release

Operation

Evaporator 

temperature 

error

When the Evaporator temperature 
is 32 ℉ or more after 30 minutes 

passed during the ice making

Check refrigerant 

leakage

Check sensor and 

attachment abnormality

Resupply power 

after resolving 

cooling problem

Stop ice 

making

Evaporator 

temperature 

error

When the Evaporator temperature 

is over 23 ℉ after 30 minutes 

passed

Check refrigerant 

leakage

Check sensor and 

attachment abnormality

Resupply power 

after resolving 

cooling problem

Keep on ice 

making

Temperature 
sensor error 

Displayed when temperature 

sensor is open or shorted.

Check sensor and 

attachment abnormality

Start operation 

after sensor part 

repair

Stop ice 

making

High 

pressure 

switch error

Condenser dust, fan motor failure, 

cold cycle abnormality, etc.

Remove dust,

Check Fan motor 

Check for abnormal 

cold cycle

Automatic return 

after action

Stop 

compressor,

Stop 

motor after 

operating 10 

seconds.

High 

pressure 

switch error

Occurs when High pressure 

switch is OPEN 3 times or more

Contact service 

representative

Start operation 

after action

Stop 

compressor,

Stop 

motor after 

operating 10 

seconds.

Water supply 

error

When water level is not detected 

by the water level sensor due to 

no water supply for 120 seconds.

Water supply pressure 

check

Water level sensor 

check

Start operation 

after action

Stop ice 

making

Water level 

sensor defect

At the start of ice making, when 

the upper and lower limits are 

not detected by the water level 

sensor for 60 seconds

Replacement of Water 

Level Sensor

Start operation 

after action

Stop ice 

making

Motor 

restraint

Occurs when Evaporator inlet / 

outlet temperature is 3.2 ℉ or 

less for 2 minutes.

Poor water supply, Agitator 

restraint, Ice jams due to scale

Unlock ice jams

Check water supply 

line

Check motor restraint 

fault 

Start operation 

after action.

Machine stops 

after 3 repetitions

Stop ice 

making

① When Error occurs, the front use button (ICE-WATER-ICE & WATER) of the door lights alternately
    to the left and right. Restart after action. 
② When the button is lit alternately to the left and right, open the door and press the bottom setting 
    button of the control buttons, Error display will appear.

Summary of Contents for ID-0300-AN

Page 1: ...on is different it can not be used This product is designed for indoor installation Please be sure to install it indoors The external appearance design color and or components of this machine may be c...

Page 2: ...e product Button operation Function button description FND display window Three drainage functions forced drainage automatic draining water drainage Stop switch 7 Maintenance repair and sanitization M...

Page 3: ...f the voltage specification is different it may cause malfunction or accident Warning Caution SHOULD BE DONE PROHIBITION GROUNDED DO NOT DISASSEMBLE DO NOT TOUCH DISCONNECT POWER PLUG An electrical fi...

Page 4: ...a risk of fire or electric shock There is a risk of fire due to electric shock or short circuit Risk of explosion or fire Do not place heavy objects or containers containing water on the ice maker Do...

Page 5: ...of a current leak electric shock and or fire Be sure to contact the customer service center if the power cord or plug get peeled or damaged Prohibition Do not bend the power cord severely or allow it...

Page 6: ...rvoir may break or become damaged The cord or plug may be peeled and there is a risk of fire or electric shock If the cord or plug is peeled or damaged be sure to ask the service to replace it Disasse...

Page 7: ...not plug in multiple plugs at the same time Connecting multiple plugs to a power strip will cause a fire Disconnect power plug When not in use for a long time remove ice and water to prevent winter fr...

Page 8: ...ction of the ice maker Caution If there is a risk of slippery water or oil on the floor near the ice maker please wipe it Hand over When transferring this ice maker to another person please hand it al...

Page 9: ...erant R 404A 11 29 oz Deceleration motor Power Supply AC 115 V 60 1PH Rated output 80 W Discharging method Solenoid Installation environment standard Specification 50 100 10 38 Water temperature 50 90...

Page 10: ...stomer Satisfactio n 3 Appearance and Size Front Top Bottom Rear 16 6 Unit inch 31 3 31 9 Drain box Height adjustable feet Display panel Ice discharge lever Filter Water connection NPT 3 8 NPTF 3 4 Ic...

Page 11: ...11 Left side Right side 24 9 27 9 14 5 11 5...

Page 12: ...50 100 Where the space with the wall is reserved For normal operation install the ice maker at least 7 8 inch away from the wall For cleaning and maintenance of the auger 39 4 inch space should be res...

Page 13: ...wing Since the product makes use of water proper water supply and draining facility are required Water may leak during installation or operation for diverse reasons Thus proper draining must be prepar...

Page 14: ...ove the lower set screws of the drain box then loosen the set screws on the top of the front panel and pull out the front panel taking both sides 3 Side panel Open the door loosen the screws on the to...

Page 15: ...and drainage Please connect with an inner diameter of 0 78 or more for the ice making drain hose and the drain outlet should be 1 97 above the drain floor level If the drain outlet dip in the drainage...

Page 16: ...unding terminal If you are using an AC outlet without a ground terminal connect the ground wire to the copper plate and bury it in the ground Do not ground in these places Never connect to a gas pipe...

Page 17: ...e front door and turn on the power switch to start the Ice making operation Turn the ICE MAKING OFF WASH switch to ICE MAKING There is a slight difference depending on the ambient temperature and wate...

Page 18: ...can simultaneously discharge ice and water for the time set in F1 When ERROR occurs ICE WATER ICE WATER button will flicker in order and will disappear when restarting after the action against the ER...

Page 19: ...terval 1 0 hour 0 5 9 5 hours every 30 minutes F 6 ICE WATER volume control 1st 2nd digits Ice time Default 5 seconds up to 99 seconds 3rd 4th digits Water time Default 5 seconds up to 99 seconds F 7...

Page 20: ...Turn the power switch off and then on again the ICE MAKING OFF WASH switch at ICE MAKING position to operate the function Clean the water line and ice making cylinder thoroughly FND 1st 2nd drain tim...

Page 21: ...power switch and press the DOWN SET button at the same time for 3 seconds with any signal on the FND window Forced drainage will be done for 30 seconds 2 Turn off the power switch and disconnect the...

Page 22: ...ix months Ice maker Storage Bin Clean and sanitize according to the sanitizing instructions given in the manual Gear motor and Drain Tray Check and wipe with a clean cloth and warm water Extruding Hea...

Page 23: ...mild detergent However when the rust has gotten really bad it must be removed with 15 nitric acid solution or commercially available stainless steel cleaner 4 Rust from exhaust gas or acid rain In env...

Page 24: ...n is completed after 5 minutes turn off the 3 step switch and turn off the Main switch 4 After injecting 1 5L of sterilizing liquid into the water tank leave it for 10 minutes 5 After activating in th...

Page 25: ...N turn the ICE MAKING OFF WASH switch to ICE MAKING and keep the operation until the Sanitizer solution is exhausted and the ice production stops 12 Switch the ICE MAKING OFF WASH switch to the WASH p...

Page 26: ...26 We Think of Customer Satisfactio n 8 Circuit Diagram...

Page 27: ...n High pressure switch is OPEN 3 times or more Contact service representative Start operation after action Stop compressor Stop motor after operating 10 seconds Water supply error When water level is...

Page 28: ...3 Is water working Check the water source 4 Is water valve working Check and contact the customer service center 3 Takes too long to make ice cubes 1 Ice maker is too dirty too much dust Air cooled t...

Page 29: ...ation due to the movement of the product moving etc 8 Failure due to defect of other company s product 9 In the case of malfunctions caused by consumables or options not specified by us 10 Failure or...

Page 30: ...R NUT 301176800 6 MICRO SWITCH 355018100 22 STOPER PAN 317205700 7 SHAFT PLATE SENSOR 314043600 23 AGITATOR ASSY 436003300 8 PLATE SENSOR 318039000 24 ICE BASE PLATE 301177500 9 HOPPER FOAM ASSY 44200...

Page 31: ...PANEL DOWN 317206700 26 BKT DRAIN WATER SOL VALVE 301179900 8 SHUTTER LEVER 309005800 27 ASSY SHUTTER 427059300 9 ASSY ANGLE 444016000 28 SPOUT 318038700 10 AIR FILTER 640009000 29 WATER SPOUT 301180...

Page 32: ...3240433 01 Online Internet Service warranty registration http www icetroamerica com...

Reviews: