24
We Think of Customer Satisfactio
n
NO
WATER
ICE
OFF DRAIN
TEMP
ERROR
MOTOR
ERROR
POWER LAMP(GREEN)
- Lamp on when power is on.
●Blinking(every 2 seconds) : in time of automatic cleaning.
FULL LAMP(YELLOW)
- Lamp on when ice become full.
NO WATER LAMP(YELLOW)
- Lamp on when water supply is short.
TEMP. ERROR LAMP(RED)
- Lamp on when temperature sensor detects unusual conditions.
●Lamp on : On when condenser temperature is more than 75℃(167℉),
Off when it is below 60℃(140℉)
●Lamp blinking(every 1 second) : Evaporator temperature is more than 3℃(37.4℉)
●Lamp blinking(every 4 seconds) : Evaporator temperature is low, less than 1℃(38.8℉),
Off when it is more than 10℃(50℉)
MOTOR ERROR LAMP(RED)
- Lamp on when motor runs lower than certain speed level due to resistance.
TEMP. AND MOTOR LAMP(RED)
●Both lamps blinking(every 2 seconds) : When evaporator outgoing temperature
is low(less than -18℃(-0.4℉))
●Both lamps on : Refrigerant high pressure sensor is activating.
POWER FULL NO WATER TEMP MOTOR All lamps blinking
●Components are needed to be checked / Notice for exchange (every 1hour) :
Giving signal for 1 minute (It gives the signal after 10,000 hour to 11,000 hour operation.)
< Components that are needed for regular check-up or exchange >
- The extruding head, the bottom housing, the mechanical seal, the geared motor
6. Product Status Indication Lamp Guide
- When all the 5 lamps blink, it means the components that are needed for regular check-up
(please refer to the below) are needed to be changed, so please contact the distributor
(the parts will be provided at a cost).
- If not changing the parts, it may cause more cost on repair.
Caution