ANALYZING WHY AN ERROR CODE STOPPED THE ICE
MACHINE (CONTINUED)
ERROR CODE #3
Error Code 3 - If the evaporator temperature exceeds
23°F after 30 minutes in the freeze cycle, the
machine will continue to run and display Er_3 on the
FND.
Possible cause checklist
Refrigeration System
•
Overcharged (too much refrigerant).
•
TXV flooding the evaporator.
•
Hot gas valve leaking by.
•
Headmaster stuck in bypass
(REMOTE ONLY)
.
Electrical System
•
Suction-line thermistor open or shorted.
•
Defective fan cycling control.
Air System
•
Improper Air Ventilation.
•
Air filter or condenser needs cleaning.
•
Condenser discharge air recirculation.
Water System
•
Water inlet valve leaking by.
•
Water regulator restricting water flow
(WATER-COOLED ONLY).
68
Summary of Contents for IM Series
Page 1: ...Revision Date 1 24 22 IM Series Air Water Remote Ice Machines Technician s Handbook ...
Page 2: ......
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK 14 ...
Page 17: ...How to Read a Serial Number Full Serial Number 16 ...
Page 35: ...THIS PAGE INTENTIONALL Y LEFT BLANK 34 ...
Page 48: ...Flexible Numeric Display FND Functions 47 ...
Page 93: ...THIS PAGE INTENTIONALLY LEFT BLANK 92 ...
Page 106: ...Testing the water level sensor Before S N Starting With VC 105 ...
Page 134: ...SERVICE REMOTE RECOVERY EVACUATION CONNECTIONS 133 ...
Page 145: ...THIS PAGE INTENTIONALLY LEFT BLANK 144 ...
Page 155: ...THIS PAGE INTENTIONALLY LEFT BLANK 154 ...
Page 157: ...Wiring Diagram 156 ...
Page 158: ...PCB Layout 157 ...
Page 159: ...PCB Dip Switches 158 ...
Page 161: ...SPACE FOR TECHNICIAN S NOTES ...
Page 162: ...SPACE FOR TECHNICIAN S NOTES ...
Page 163: ...SPACE FOR TECHNICIAN S NOTES ...
Page 164: ...SPACE FOR TECHNICIAN S NOTES ...
Page 165: ......