ANALYZING WHY AN ERROR CODE STOPPED THE ICE
MACHINE (CONTINUED)
ERROR CODE #13
Error Code 13 - If the high pressure switch opens, the
machine will stop and display Er_13 and close when the
pressure drops.
Possible cause checklist
Refrigeration System
•
Overcharged system (too much refrigerant).
•
Hot gas valve leaking by.
•
Headmaster stuck in bypass.
(REMOTE ONLY)
•
Improper air ventilation.
•
Air filter or condenser needs
cleaning.
•
Condenser blocked.
•
Condenser discharge air
recirculation.
•
Condenser fan motor failure.
•
Condenser fan blade broken.
Water System (WATER-COOLED ONLY)
•
Insufficient water supply.
•
Insufficient water pressure.
•
Water regulator restricting water flow.
Air System
71
Summary of Contents for IM Series
Page 1: ...Revision Date 1 24 22 IM Series Air Water Remote Ice Machines Technician s Handbook ...
Page 2: ......
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK 14 ...
Page 17: ...How to Read a Serial Number Full Serial Number 16 ...
Page 35: ...THIS PAGE INTENTIONALL Y LEFT BLANK 34 ...
Page 48: ...Flexible Numeric Display FND Functions 47 ...
Page 93: ...THIS PAGE INTENTIONALLY LEFT BLANK 92 ...
Page 106: ...Testing the water level sensor Before S N Starting With VC 105 ...
Page 134: ...SERVICE REMOTE RECOVERY EVACUATION CONNECTIONS 133 ...
Page 145: ...THIS PAGE INTENTIONALLY LEFT BLANK 144 ...
Page 155: ...THIS PAGE INTENTIONALLY LEFT BLANK 154 ...
Page 157: ...Wiring Diagram 156 ...
Page 158: ...PCB Layout 157 ...
Page 159: ...PCB Dip Switches 158 ...
Page 161: ...SPACE FOR TECHNICIAN S NOTES ...
Page 162: ...SPACE FOR TECHNICIAN S NOTES ...
Page 163: ...SPACE FOR TECHNICIAN S NOTES ...
Page 164: ...SPACE FOR TECHNICIAN S NOTES ...
Page 165: ......