ANALYZING WHY AN ERROR CODE STOPPED THE ICE
MACHINE (CONTINUED)
ERROR CODE #16
Error Code 16 - If water level sensor detects water
at the high-level probe at the end of a freeze cycle, the
machine will stop and display Er_16. The machine will
resume operation if the problem is resolved after
automatically attempting to re-sart every hour.
Possible cause checklist
Water System
•
Water level sensor faulty or in need of
cleaning.
•
Water inlet valve suck open.
•
Faulty PCB.