Freeze Cycle Discharge Pressure Low Checklist
Improper Installation
•
Refer to “Installation/Visual Inspection Checklist”
on page 32.
Air Cooled Condensers
•
Defective headmaster valve, won’t bypass
“Headmaster Valve” on page 118.
•
Defective fan cycle control, stuck closed
“Fan Cycle Control” on page 113.
Water Cooled Condensers
•
Water Regulating Valve out of adjustment.
•
Water Regulating Valve Defective
Other
•
Undercharged.
•
Wrong type of refrigerant.
•
Non-Icetro components in system.
•
Liquid line/component restricted.