15
The soft cream level is set for the ingredients (vanilla) designated by the maker.
Depending on the ingredients, you will need to adjust it properly. Please follow the
instructions from our company when changing the level for the ingredients.
For Your
Information
Detailed description of each mode
If you press the "Set" button lightly, you can
enter the mode to check the setting as below.
Use the“
▼
”and“
▲
”buttons to see the settings.
1-1: Check ice cream level settings
You can check the current setting for the ice cream. If the
displayed value is higher than the no-load current (1-2),
the ice cream becomes harder and if lower,
the ice cream becomes softer.
1-2: Check the ice cream default level
It is the no-load current of the dasher motor.
It is the current consumed by the dasher motor when the
ingredients are in the liquid status.
1-3 : Check the currently supplied voltage.
It is the power supplied to the machine.
If the voltage is not correct after installation,
call for service.
1-4 : Check the storage temperature in the mixing tank.
You can check the temperature inside the mixing tank.
1-5 : Check the voice announcement
You can check whether a voice announcement is available.
1-6 : Check the program version
You can check the versions of the main
PCB and the display PCB.
"n" is for the main PCB and "d" is
for the display PCB.
Change the setting
Summary of Contents for ISI-300TA
Page 36: ...36 Circuit diagram ...
Page 39: ...39 MEMO ...
Page 40: ...3240342 01 Online Internet Service http www icetro com ...