37
REMOVAL FROM SERVICE/WINTERIZATION
Self-contained Air-cooled ice machines
1. Descale and sanitize the ice machine.
2. Set the 'ICE/OFF/WASH' switch to the 'OFF' position.
3. Turn off the water supply, disconnect and drain the
incoming ice-making water line at the rear of the ice
machine and drain the water trough.
4. Energize the ice machine, wait o for the water inlet
valve to open, and blow compressed air into the incoming
water openings in the rear of the ice machine to remove
all water.
5. Set the 'ICE/OFF/WASH' switch to 'OFF' and
disconnect the electric power at the circuit breaker or the
electric service switch.
6. Fill spray bottle with sanitizer and spray all interior
food zone surfaces. Do not rinse and allow to air dry.
7. Replace all panels.