ERROR CODE
FULL indicator
(yellow)
flashing:
1.
Water Supply Issue: High-level float detects water
10 minutes sooner than the low-level float.
Possible cause checklist
•
Check that the float(s) are properly installed.
•
Check that the float(s) are working properly.
•
Check all wire connections between the float(s)
and the control board (PCB).
ERROR CODE
E
R
ROR
indicator
(red)
flashing:
1.
High Pressure Issue: High pressure switch open for
more than 10 seconds.
2.
High Pressure Issue: High pressure switch open for
more than 10 seconds, 3 consecutive times.
Possible cause checklist
•
Check that the air filter or condenser is not dirty.
•
Check that the ambient air temp is below 100°F.
•
Check that there are no restrictions to air flow.
•
Check that discharge air is not being recirculated.
•
Check the refrigerant charge.
•
Check that the hot gas valve is working properly.