DX8
Dual Balance Charger/Discharger/DC Power
- 30 -
Select the test mode and go to the following
corresponding
interface.
Pulse Measurement
Connect the signal receiver or transistor with the multifunctional port like below, which can measure their pulse signal:
Select
SYSTEM MENU
→
Pulse
Test
to enter the pulse test interface, only
CH-1 J1
port supports the input signal of Pulse
Measurement.
1
.
Type:
Analog servo (1500us/50Hz)
Digital servo (1500us/333Hz)
Digital servo (760us/560Hz)
User: Pulse Center: 700us-1600us
Frame Rate: 40Hz-700Hz
45°Pulse Traveling:100us-1000us
2
.
Liner test
3
. Fixed point test
4
. Auto CW/CCW Test
Liner Test:
When turning the knob,
the pointer deflects with the setting
value of
Step,
and the servo responds
accordingly.
Fixed Point Test:
When turning the
knob, the pointer deflects among
each setting value and the servo
responds accordingly.
Auto CW/CCW Test:
Click
Test
button then the pointer deflects the
setting times at a set rate back and forth
among each setting values, and the
servo responds accordingly.
+
-
S
-
S
Signal Receiver or
Transistor
1. Pulse frequency
2. Pulse period
3. Positive pulse duty cycle and pulse width
4. Negative pulse duty cycle and pulse width
2
2
3
4