4.2 Start Up Procedure

(1) When  placing  the  iCleaner-120 

in  the  pool:  you  must  wobble 
the  iCleaner-120  according 
Pic.4.2.1  to  make  sure  the  air 
inside is released when you put 
the iCleaner-120 in the water,   

  So it will automatically sink to 

the bottom of pool.

 (2) Start: Press the “ON” button, 

LED  “POWER”  indicator. 
And “0.5H” cycle time LED 
will illuminate(see pic.4.2.2)

    You  may  select  0.5Hr,  1Hr  or 

2Hrs cleaning time using the 

“       ”

button  on  the 

Remote  Control  and  relative 
L E D   i n d i c a t o r s   w i l l  
illuminate on the Power Box 
when selected.

Pic.4.2.1

Pic.4.2.2

- 7 -

All manuals and user guides at all-guides.com

Summary of Contents for iCleaner-120/SPC1

Page 1: ...120 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...o avoid personal injury Users are only permitted to perform maintenance described in this manual Any tampering with the Motor Box or Power Supply will void the warranty Ensure the iCleaner 120 is fully submerged before turning the power box on If the iCleaner 120 is not going be used for a long time make sure to disconnect the power keep it clean and put it in a safe dry and well ventilated area I...

Page 3: ...manually Manual cleaning the Remote Control can be used to clean specific areas immediately Self protection out of water Impeller decelerates to a stop in twenty five seconds if the iCleaner 120 senses it is no longer in water to prevent personal injury and to protect the water pump Stop protection the iCleaner 120 will stop if foreign matter retards the Impeller 2 2 Product Parameters iCleaner 12...

Page 4: ...ts List Main Body Parts Pic 2 3 2 3 Filter Net water retaining board Base Plate Support Frame Filter Bag Base Plate Latch Drive Belt Guide Vane Hook Floating Cable All manuals and user guides at all guides com ...

Page 5: ... Power Box Parts 4 All manuals and user guides at all guides com ...

Page 6: ...6 7 8 3 Packing List Part Name Unit Body Power Box Remote Control Battery Guide Vane User Manual Warranty Card Certificate of Quality Serial Number Remarks Host Quantity 10 11 Spare Parts Synchronous Belt All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...o an outside AC power of 100v 240v 50 60Hz see Pic 4 1 2 For the complete connection guide please refer Pic 4 1 3 Notices Do not allow the Power Box to come in contact with water Please ensure the Power Box is Kept in a shady dry ventilated area Refer Page 1 Safety Warning Pic 4 1 1 Pic 4 1 2 6 Unit Body All manuals and user guides at all guides com ...

Page 8: ...ter So it will automatically sink to the bottom of pool 2 Start Press the ON button LED POWER indicator And 0 5H cycle time LED will illuminate see pic 4 2 2 You may select 0 5Hr 1Hr or 2Hrs cleaning time using the button on the Remote Control and relative L E D i n d i c a t o r s w i l l illuminate on the Power Box when selected Pic 4 2 1 Pic 4 2 2 7 All manuals and user guides at all guides com...

Page 9: ...he iCleaner 120 gently onto the floor unlock the Latch on the Base Plate Pic4 3 2 and remove the Filter Bag from Base Plate clean the Filter Bag Pic 4 3 3 once clean place the Filter Bag on its frame reassemble the Base Plate and put it back into the iCleaner 120 once the Filter Bag is dry Note When re fitting the Filter Bag to the Base Plate please ensure the long sides of the Filter Bag are smoo...

Page 10: ...Cleaning The Remote Control Pic 4 4 1 includes On Off Power Button LED Light Indicator Direction Button Timer Button Floor Only Cleaning On Off Power Button Turn on or Turn off iCleaner 120 Direction Button Control iCleaner 120 s movement Backward Left Rotation and Right Rotation Timer Button Select the timing mode from 0 5hour 1 hour and 2hours Floor Only Cleaning To clean the Floor Only press To...

Page 11: ...e clockwise to remove from the iCleaner 120 Pic 5 1 1 Step 2 Use a Phillips head screw driver to remove the bolt in the Impeller according the diagram Pic 5 1 2 Step 3 Replace the new Impeller and assemble Impeller and Guide Vane Guide Vane All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ...t if they are badly worn or broken Step 1 Invert the iCleaner 120 on the floor remove the Base Plate Push latch to unlock the Base Plate Pic 5 2 1 Step 2 Remove the Filter Net from the iCleaner 120 while pressing the Latch according to the diagram Pic 5 2 2 Pic 5 2 2 All manuals and user guides at all guides com ...

Page 13: ... on the Side Cover to remove the Side Cover Pic 5 2 3 Pic 5 2 3 Step 4 Remove the Sponge Wheel Shaft Sleeve Drive Wheel Shaft Sleeve and take off the Drive Belt Pic 5 2 4 Pic 5 2 4 8 Drive Wheel Shaft Sleeve 7 Sponge Wheel Shaft Sleeve 9 Drive Belt All manuals and user guides at all guides com ...

Page 14: ...te remove the Synchronous Belt Pic 5 2 5 Step 6 Slide the old sponge wheels off and replace with new sponge wheels Pic 5 2 6 Remove the Rolling Brush 1 Drive Wheel Baffle Plate 2 Drive Wheel 3 Synchronous Belt 13 Pic 5 2 6 All manuals and user guides at all guides com ...

Page 15: ...l Pic 5 2 7 to aeeemble the Synchronous Belt 14 wheel axle Pic 5 2 7 Pic 5 2 8 Step 8 Assemble the Drive Belt on the Roller Wheel Pic 5 2 8 Step 9 Assemble Drive Wheel Baffle Plate to the Drive Wheel Pic 5 2 9 Pic 5 2 9 Inside Inside Outside Outside Inside Outside All manuals and user guides at all guides com ...

Page 16: ...to iCleaner 120 pressing down until the latches lock into place Pic 5 2 13 Replacing the Sponge Wheels and Synchronous Belt is now completed Pic 5 2 13 Step 10 Put the Drive Wheel Sleeve and Roller Wheel Sleeve to Side Covers Pic 2 2 10 Step 11 Put the Side Covers to Host and fasten it with bolts nuts Pic 5 2 11 7 Roller Wheel Sleeve 8 Drive Wheel Sleeve Pic 5 2 10 All manuals and user guides at a...

Page 17: ...d to one end remove the water retainining board carefully Step 2 Insert one end of the water retaining board into the locating holes on the base plate then insert the other end of the water retaining board into the base plate and make sure the water retaining board does not have a bend in it if it does gently push the hinged edge until it clicks into position Note The water retaining board is fitt...

Page 18: ... Filter Bag is loosen or broken Dirt is too fine for the filter bag Plug in the power lead Check the connection clean the Impeller Replace the Impeller clean the Filter Bag replace the Belt Synchronous Clean Filter Bag clean the Filter Bag replace the Belt Synchronous Replace the Sponge wheel replace axis sleeves Wobble iCleaner 120 and make sure air released Replace broken filter bag Please turn ...

Page 19: ...ater pump motor and impeller about exceptions Indicator light Solution Failure Green light flashing The iCleaner has stopped due to lack of water Return the robot to deeper water and restart Yellow light flashing The Motor Pump inside the robot has over heated Contact the supplier for support Blue light flashing The robot is upside down Turn the iCleaner over and restart using the remote control o...