Water-to-syrup
ratio to low or
too high
1.
2.
3.
Syrup flow regulator not properly
adjusted.
CO2 gas pressure in syrup tanks
insufficient.
Syrup tubing I.D. insufficient.
1.
2.
3.
Adjust water-to-syrup ratio (see
dispensing station installation
instructions.
Adjust low-pressure regulator as
instructed.
Increase syrup tubing I.D. Note:
see “Brix instructions”
Adjustment of
syrup metering
pin does not
produce desired
water-to-syrup
ratio
1.
2.
3.
4.
5.
6.
No syrup supply.
Syrup tank quick disconnects not
secure.
Low-pressure CO2 reg-ulator out
of adjustment.
B.I.B. QCD disconnected or
improperly installed.
Syrup line restricted.
Dirty or inoperative metering pin
or piston in syrup flow control.
1.
2.
3.
4.
5.
6.
Replenish syrup supply as
instructed.
Secure quick disconnects.
Adjust low-pressure CO2
regulator as instructed.
Connect B.I.B. disconnect
securely.
Clear restriction or replace
restricted line.
Disassemble and clean syrup flow
control. Adjust water-to-syrup
ratio, see “Brix instruction”.
6-5