Electrical Requirements: The cooling unit requires a 115 VAC, single phase, 60 Hertz
power
circuit.
Topper
Topper-J
Circuit Ampacity ............10.5 Amps ........ ......................... 3.8 Amps
Condensing Unit............2.5 Amps .......... ......................... 2.5 Amps
Water Pump Motor ........6.2 Amps .......... ......................... NA
Transformer....................5 Amps .......... ......................... .5 Amps
Agitator...........................8 amps .......... ......................... .8 amps
Water Filter Recommended (Optional) See Manufacturer Specifications for Operating Conditions
Pressure
Incoming Water Pressure Regulator (Optional) .......................................... 25 – 40
C02 High-pressure Regulator (Carbonated units only) PSI........................ 70 – 75
C02 Low-pressure Regulator (Carbonated/Flavored units only) ................ BIB Approx. 40 PSI
C02 Low-pressure Regulator (Carbonated/Flavored units only) ................ FIGAL Approx. 30 PSI
C02 Low-pressure Regulator (Optional) ..................................................... FIGAL Approx. 30 PSI
C02 Diet Drink Pressure Regulator (if required) ......................................... 6 - 10 PSI
DISPENSING VALVES Ambient Operating Temperature .......................... 40 F to 100 F
Electrical Requirements: Operating Voltage .......................... 24VAC, 6Ohz
1-2