13
5.
Minimum Deadband
(1°F to 9°F) (1°C to 5°C)
Set the minimum separation between heat setpoint and cool setpoint in Auto Changeover Mode.
Press the
or
to set deadband value.
Press
to advance to the next screen.
CONFIG
7.
Auxiliary Delay ON
(0-60 minutes)
Set the delay time in minutes for auxiliary heat to be locked out after a call for second stage. This
extra savings feature is used to temporarily lock out auxiliary heat devices, allowing just heat
pump to try to satisfy heat call.
Press the
or
to select. Press
to advance to the next screen.
CONFIG
HEAT
6.
Heat Source:
There are six heat source settings:
WARNING!
:
Incorrect settings can damage system and/or cause potentially dangerous conditions. Use the code
described in Configuration and Thermostat Lock.
Non-Heat Pump
CONFIG
Electric
CONFIG
Gas
Heat Pump
CONFIG
Heat Pump with
2 compressors
and Heat Active
Reversing Valve
CONFIG
Heat Pump with
2 compressors
and Cool Active
Reversing Valve
CONFIG
Heat Pump with
1 compressor
and Heat Active
Reversing Valve
CONFIG
Heat Pump with
1 compressor
and Cool Active
Reversing Valve