Room Temperature Offset
(+9°F to -9°F) (+4.5°C to -4.5°C)
Adjust to calibrate displayed room temperature to match actual room temperature.
Press the
or
to select.
Press
to advance to the next screen.
CONFIG
CONFIG
14.
Maximum Cycles Allowed Per Hour
(- -, 2-6)
= as many as needed, 2-6 = maximum cycles/hour
Press
or
to select.
Press
to advance to the next screen.
WARNING!
:
Incorrect settings can damage system and/or cause potentially dangerous
conditions. Use the code described in Configuration Safety Lock to access this screen
setting
15.
Temperature Sensor
(
L
,
r
,
A
,
r
sleep)
Note:
If there is no remote sensor, option 1 (L) must be selected. May only be used with remote
temperature sensor 1.
CONFIG
Appears only for non-heat pump systems and heat pumps without an outdoor sensor.
1.
L
– Only on-board sensor determines room temperature.
3.
A
– Average temperature of on-board and remote sensor.
2.
r
– Only remote sensor determines room temperature.
4.
r
Sleep
– Only on-board sensor will be used until SLEEP period,
and then only remote sensor is used for SLEEP period.
Press
or
to select.
Press
to advance to the next screen.
16.
Fan Delay Off Time
(0, 30, 60, 90 seconds)
Select the amount of time the fan continues to operate after the cool/heat demand has been
satisfied. Functions for cooling, heat pumps and electric heat.