Electrical rating:
• 24 VAC (18-30 VAC)
• DC Power: 3.0 VDC (2 “AA” batteries included)
• 1 amp maximum per terminal
• 3 amp maximum total load
Temperature control range:
45°F to 90°F (7°C to 32°C)
Accuracy:
± 1°F (± 0.5°C)
System configurations:
1-stage heat, 1-stage cool, heat pump, gas, oil, electric
Timing:
Anti-short Cycle: 5 minutes
Backlight Operation: Battery for 5 seconds, hardwired for 10 seconds
Terminations:
RC, RH, W, Y, B, O, G, C
Specifications
WARNING!
:
Always turn off power at the main power supply before installing, cleaning, or removing
thermostat.
• This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
• Do not short across terminals of gas valve or system control to test operation; this will damage your
thermostat and void your warranty
• All wiring must conform to local and national electrical and building codes
• Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your
A/C system and cause personal injuries
• Use this thermostat only as described in this manual
Important Safety Information
Package includes:
SimpleComfort
®
2010 thermostat on base, thermostat cover, wiring labels, screws and
wall anchors, Installation, Operation and Application Guide
Tools required for installation:
Drill with 3/16” bit, hammer, screwdriver