ONE-YEAR LIMITED WARRANTY
The Seller warrants its products against defects in material or workmanship for a period of one (1) year from the
date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a non-case credit for
the purchase prices of the goods which are provided to be defective. The warranty and remedies set forth herein
do not apply to any goods or parts thereof which have been subjected to misuse including any use or application
in violation of the Seller’s instructions, neglect, tampering, improper storage, incorrect installation or servicing not
performed by the Seller. In order to permit the Seller to properly administer the warranty, the Buyer shall: 1) Notify
the Seller promptly of any claim, submitting date code information or any other pertinent data as requested by the
Seller. 2) Permit the Seller to inspect and test the product claimed to be defective. Items claimed to be defective
and are determined by Seller to be non-defective are subject to a $30.00 per hour inspection fee. This warranty
constitutes the Seller’s sole liability hereunder and is in lieu of any other warranty expressed, implied or statutory.
Unless otherwise stated in writing, Seller makes no warranty that the goods depicted or described herein are fit for
any particular purpose.
LIAF020
Patent No. - Design: 424,953
Patent No. - Thermal Intrusion Barrier: 6,597,275
Patent Pending - SimpleSet
TM
Target Programming Technology
7313 William Barry Blvd., North Syracuse, NY 13212
(
Toll Free) 800-365-5525 (Phone) 315-233-5266 (Fax) 315-233-5276
www.icmcontrols.com
Table of Contents
To Install Thermostat
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the OFF position before removing the existing
thermostat.
IMPORTANT:
Thermostat installation must conform to local and national building and electrical codes and
ordinances.
Note:
Mount the thermostat about five feet above the floor. Do not mount the thermostat on an outside wall, in
direct sunlight, behind a door, or in an area affected by a vent or duct.
1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate circuit
breaker off.
2. To remove cover, insert and twist a coin or screwdriver in the slots on the top corner of the thermostat.
3. Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire opening
in the base of the thermostat).
4. Mark the placement of the mounting holes.
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the OFF position before removing the existing
thermostat.
1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate circuit
breaker off.
2. Remove cover of old thermostat. This should expose the wires.
3. Label the existing wires with the enclosed wire labels before removing wires.
4. After labeling wires, remove wires from wire terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to install this thermostat.
To Remove Existing Thermostat
2-Stage Heat/ 2-Stage Cool
Manual Changeover
Hardwired
SC3211L
Programmable Electronic Thermostat
Installation, Operation & Application Guide
For more information on our complete range of American-made
products – plus wiring diagrams, troubleshooting tips and more,
visit us at
www.icmcontrols.com
Specifications
...............................................................................................................................................................1
Important Safety Information ........................................................................................................................................1
Package Contents/Tools Required ...............................................................................................................................1
To Remove Existing Thermostat ...................................................................................................................................2
To Install Thermostat ....................................................................................................................................................2
Wiring Diagrams
...........................................................................................................................................................4
Single Compressor, Cool Active .................................................................................................................................4
Dual Compressor, Cool Active
....................................................................................................................................4
Single Compressor, Heat Active .................................................................................................................................5
Dual Compressor, Heat Active
....................................................................................................................................5
Parts Diagram
...............................................................................................................................................................6
Operation ......................................................................................................................................................................6
Setting the Setpoint Temperature .................................................................................................................................6
Configuration Mode
......................................................................................................................................................7
Configuration Mode Settings
........................................................................................................................................8
Starting the Thermostat ..............................................................................................................................................11
Testing the Thermostat ...............................................................................................................................................12
Operating Modes ........................................................................................................................................................13
Setting the Time and Day of the Week
.......................................................................................................................14
Programming ..............................................................................................................................................................15
Lockout Feature..........................................................................................................................................................16
Factory Preprogramming ............................................................................................................................................17
Personal Program Schedule.......................................................................................................................................17
SimpleSetTM Field Programming...............................................................................................................................19
Troubleshooting ..........................................................................................................................................................20
Specifications
Electrical rating:
• 18-30 VAC
• 1 amp maximum per terminal
• 4 amp maximum total load
Temperature control range:
45°F to 90°F (7°C to 32°C)
Accuracy:
± 1°F (± 0.5°C)
System configurations:
2-stage heat, 2-stage cool, heat pump
Terminations:
R, C, Y1, Y2, W2, O, B, G, L, E
Important Safety Information
WARNING!
:
Always turn off power at the main power supply before installing, cleaning, or removing
thermostat.
• This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
• All wiring must conform to local and national electrical and building codes
• Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system
and cause personal injuries
• Use this thermostat only as described in this manual
Package Contents/Tools Required
Package includes:
SimpleComfort
®
SC3211L
thermostat on base, thermostat cover, wiring labels, screws and wall
anchors, Installation, Operation and Application Guide.
Tools required for installation:
Drill with 3/16” bit, hammer, screwdriver.
5. Set thermostat base and cover away from working area.
6. Using a 3/16” drill bit, drill holes in the places you have marked for mounting.
7. Use a hammer to tap supplied anchors in mounting holes.
8. Align thermostat base with mounting holes and feed the control wires through wire opening.
9. Use supplied screws to mount thermostat base to wall.
10. Insert stripped, labeled wires in matching wire terminals. See “Wiring Diagrams” section of this manual
(Pages 4-5).
CAUTION!:
Be sure exposed portion of wires does not touch other wires.
11. Gently tug wire to be sure of proper connection. Double check that each wire is connected to the proper
terminal.
12. Replace cover on thermostat by snapping it in place.
13. Turn on power to the system at the main service panel.
14. Test thermostat operation as described in “Testing the Thermostat” (Page 12).
Lockout Feature
From any of the screens on Page 15, you can press the
HOLD
(right) button to begin entering your program
schedule. The days shown on the display will all be programmed simultaneously.
Once the
HOLD
(right) button is pressed,
MORN
blinks.
Use the up or down button to select a different period (
MORN
,
DAY
,
EVE
,
NITE
).
Press
HOLD
(right) button to advance to the next screen. Transition time hour blinks.
Use the up or down button to select a different hour.
Press
HOLD
(right) button to advance to the next screen. Transition time minutes blink.
Use the up or down button to select different minutes.
Press
HOLD
(right) button to advance to the next screen. Heat set temperature displays.
Use the up or down button to adjust the heat set temperature.
Press
HOLD
(right) button to advance to the next screen. Cool set temperature displays.
Use the up or down button to adjust the cool set temperature.
Repeat above steps to program the four periods per day.
When the program schedule is complete, press and hold the
PROG
and
HOLD
buttons (pressed simultaneously) in
for 2 seconds to return to the
OFF
mode.
The
SC3211L
has a button lockout feature so the mode cannot be changed and the
temperature adjustment is limited. Select the appropriate lockout from Configuration
Mode Settings (Step 6, Page 9) of this guide.
To activate the LOC feature:
1. Simultaneously press the
PROG
,
HOLD
and
UP
buttons for 10 seconds.
2. LOC will display and the lockout function will be enabled.
To deactivate the LOC feature, repeat steps 1 and 2 above.
Factory Preprogramming
MORN
6:00 AM
DAY
8:00 AM
EVE
6:00 PM
NITE
10:00 PM
HEAT
70°F
HEAT
62°F
HEAT
70°F
HEAT
62°F
COOL
78°F
COOL
85°F
COOL
78°F
COOL
82°F
MONDAY
thru
SUNDAY
Personal Program Schedule
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
MONDAY
1
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
WEDNESDAY
3
TUESDAY
2
The
SC3211L
comes preprogrammed with the following schedule:
Use the following personal program schedule to record your settings:
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
THURSDAY
4
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
FRIDAY
5
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
MORN
DAY
EVE
NITE
HEAT
HEAT
HEAT
HEAT
COOL
COOL
COOL
COOL
SUNDAY
7
SATURDAY
6
SimpleSet
TM
Field Programming
This feature is used for transferring configuration and program schedule from the master to the target thermostat.
All thermostats for a job can be mounted and powered up. Configure and program one thermostat. This will be the
master. The master will be used to copy the program to the rest of the thermostats.
Preparing the master to Send:
1. The master must be powered by 24 VAC.
2. Verify the master thermostat is in
OFF
mode. Slide system switch to center position.
3. Remove cover of the master thermostat by gently pulling near one of the corners at the top
of the thermostat.
4. Press the
up
and
down
buttons and
CONFIG
switch simultaneously for 5 seconds.
5. The
OUT
screen displays indicating the master thermostat is ready to
transfer data.
Note:
Press the
up
and
down
buttons and
CONFIG
switch simultaneously for 5 seconds
to exit from data transfer mode and to return the master to the
OFF
mode.
6. Connect the master to the target using the 3 wire connector. Attach one end to the Master’s
FP pins and the other end to the Target’s FP pins.
Note:
Target thermostat must be powered by 24 VAC for field programming to occur
When the connection has been made correctly, the master thermostat will power up and the target will count from 6
down to 1. It will then display
LOC
confirming the data has been saved in memory.
When all target thermostats have been completed, reinstall the master thermostat.
Press the
up
and
down
buttons and the
CONFIG
switch simultaneously for 5 seconds to exit from the data transfer
mode and to return the master thermostat to the
OFF
mode.
OFF
Troubleshooting
* Reset Button Function:
Time, day and program/non-program changed to last saved settings (saved after
program or configuration change), configuration and program unchanged, ASC timer
reset to 0.
Symptom
Remedy
No display
Verify 24 VAC is at thermostat
System fan does not come on properly
Verify wiring is correct
Program schedule activates at the wrong
time
Check time (AM/PM) set on thermostat (see “Setting the Time,”
Page 14)
Thermostat turns on and off too frequently
Adjust temperature differential (see “Configuration Mode Settings,”
Page 8)
Thermostat does not follow program
Verify it is operating in Program mode (PROG solid in display);
check time (AM/PM); check if in Hold mode (PROG flashes)
“PROGram” flashes (in Hold mode)
Press Hold button to remove from Hold mode (PROG solid)
Fan runs continuously
Check Fan Auto/On switch, continuous fan operation in ON
Problem not listed above
Press reset button once*
• 7-Day Programmable
• 2-Stage Heat Pump
• Manual Changeover
•
SimpleSet
®
Target Programming
• Selectable °F or °C
• Relay Outputs
(minimum voltage drop in thermostat)
• Ideally Suited for Residential
–
Residential (New Construction/Replacement),
Light Commercial