background image

To enter different modes: 
 
To enter set-up mode:

 

Select 

MAIN*BAND 

for desired band 

Push 

SET 

to enter set mode 

Push 

LOW PRIO 

to select item 

Rotate 

DIAL

 for value/condition 

Push 

TONE DTMF 

to exit

 

 

To enter the memory banks:

 

10 banks (A to J) vs. Regular memory 000 to 199 
- Push desired band 

[M/CALL

MW] 

several times till  

  you see Bank initial appear e.g. “A”  
- Push 

[MAIN

BAND] 

for 1 sec. Till bank initial blinks 

- Rotate the same band’s 

[DIAL] 

to select the desired bank,  

  A to J. Banks that have no programing are skipped. 
- Push the 

[MAIN

BAND] 

to set the bank (initial stopes  

  blinking) 
- Rotate 

[DIAL] 

to select the contets in the bank 

- Push 

[MAIN BAND] 

for 1sec, then momentarirly again 

  to set the change and treturn to regular memory. 

 

Manually Entering Repeater values

 

 

Selecting the frequency:

 

Push 

[V/Mhz

SCAN] 

till you see the frequency with 

dashes like: 

146._ _ _ 

and multiple times to see select which 

digit to change.  The use 

[DIAL] 

to select the frequency. 

Then [

V/Mhz

SCAN] 

for ‘setting the frequncy’. 

[Note: US version may auto set the correct offset & tone,  
if not continue.] 

 
Selecting the +, -, or no Offset: 

Press 

[DIP * MON] 

to switch between 

– 

offset “

Dup-

” & 

plus offset, “

Dup

” and no offset (no Dup showing) 

 

Setting the Offset Frequency: 

Push

 [SET ,-o ] 

several times till you see “

Dup

”  

blinking in the upper lf. & current offset freq. 
Rotate 

[DIAL] 

to desired offset 

Press 

[TONE * DTMF] 

to set & exit 

 

Selecting Tone:

 

Push 

[TONE * DTMF] 

till “

T

” appears to turn on the tone 

(it defaults to 88.5). 
 

Setting the Tone value:

 

Press 

[SET ,-o ] 

several times till you see the current tone 

and “

rE

” (lower Rt. Corner) . Then rotate band 

[DIAL] 

to 

the desired tone.  Push 

[TONE * DTMF] 

to exit & set the 

new tone. 

IC-2720 

User 
Reference 
Guide 

version: 3.0

 

Produced by Ham’s for 

Hams! For personal use only 

& not associated with ICOM 

in any way. Just “Ham’s 

helping Ham’s” 

Compiled by Martin Brossman 

KI4CFS can be reached at 

KI4CFS@toinquire.com  

Photo from ICOM website  

http://www.icomamerica.com/ 

US Models only 

 

To Use Cross Band Repeat Mode: 

  - Set the frequencies on both bands  
    (Receive on VHF on left e.g. 146.550,  
     Send UHF on right e.g. 444.525) 
  * Press and hold 

LOW 

and 

DUP 

on the faceplate,  

    then quickly press 

SET

 (above the right-side  

    volume knob)  
    for two seconds, then let go of all 3 buttons 
- Two flashing 

Ls

 will appear on the display --  

   (the 

Ls

 must be flashing) 

  * To exit this function:   press 

SET 

for two seconds 

 

Turning on & off the Weather Report 

  * Press 

[M/CALL*MW] 

till you see a 

rCH-1 

or 2 or… 

     in the display. Then rotate the 

[DIAL] 

to select the   

    weather channel appropriate to your area. 

2 Meters: 144.0-148.0 MHz 

70 CM  : 420.0-450.0 MHz  

Standard 2 Meter & 70 Cm bands  

Call Channel Selection 

Push 

[M/CALL

MW] 

till you see 

‘C1’ 

or

 ‘C2’ 

select 

[DIAL] 

select call channel 

 

Enter / Program call Channel 

Select the frequency & settings   
Push 

[M/CALL

MW] 

for 1 sec.

 

Rotate 

[DIAL] 

to select the desired call channel 

“C1” or “C2” blink. 
Push 

[M/CALL

MW

] for 1 sec. To program 

(3 beeps sound & eht unite retursn to VFO mode.)

 

 

Frequency 

Left band 

Right band 

127 

Available 

Available 

222 

Available 

Not-Available 

375 

Available 

Available 

500 

Available 

Available 

900 

Not-Available 

Available 

USA & General version Frequency Bands

 

Copies can be found at: 
http://groups.yahoo.com/group/IC-2720/ 
Or http://www.toinquire.com/ham 

Reviews: