3
SET MODE
3-4
Set mode items (Continued)
D
Quiet mode “QUIET”
Turn On or OFF the Quiet mode for Selcall. See page
7-4 for details.
D
Lockout “LOCK-O”
Select the transmission Lockout function mode which
temporarily inhibits transmission.
• RP (Repeater Lockout): Locks out a repeater.
• BU (Busy Lockout):
Locks out a busy channel.
• OF (OFF):
Turns OFF the function.
D
Roger beep “RGR-B”
You can turn ON the Roger Beep function to beep to
indicate that the transmission has ended.
D
Battery Voltage “BATT”
You can set to display the Battery Voltage for 2
seconds, when you turn ON the transceiver.
D
Auto Power OFF “AP-OFF”
You can set the transceiver to automatically turn OFF
after the set period without any key operation. You can
set it to between 0.5 and 4.0 hours (0.5 hour steps) or
8.0 hours.
D
Signal Monitor “SMON”
You can select whether or not to sound a beep when
you transmit a Selcall code or DTMF code signal.
ON: A beep sounds.
OFF: No beep sounds.
D
Horn “HORN”
Select whether or not to activate the HORN terminal
when a call is received. This function is useful when a
user is away from the transceiver.
*An external horn and an optional OPC-1939
acc
cable
is
required. Ask your dealer for details.
D
RX VFO “RX VFO”
Edit the RX channel frequency. See page 8-3 for
details.
D
Scan Stop Timer “S-TIME”
You can set the Scan Stop Timer to pause (P5) or
timer scan (5/10/15). When a signal disappears, the
scan resumes after the set period of time.
5/10/15: Scan pauses for 5, 10 or 15 seconds when a
signal is detected, then resumes.
P5:
Scan pauses until the signal disappears,
and then resumes after 5 seconds
(Recommended setting).
D
Scan Restart “SCAN-R”
This function restarts the scan 10 seconds after you
stop transmitting. You can turn the function ON or
OFF.
Lockout OFF (default)
Busy lockout
Roger Beep OFF (default)
Roger Beep ON
Battery Voltage display
OFF (default)
Battery Voltage display ON
Auto Power OFF
is OFF (default)
2 hour setting
Signal Monitor ON (default)
Signal Monitor OFF
Horn is OFF (default)
Horn is ON
Scan Stop Timer
P5 (default)
10 second setting
Scan Restart OFF (default)
Scan Restart ON
Quiet mode OFF (default)
Quiet mode ON