15-22
15. ABOUT THE DV GATEWAY FUNCTION
Troubleshooting
D
Troubleshooting for the Terminal mode operation
The following chart is designed to help you correct problems which are not equipment malfunctions.
If you are unable to locate the cause of a problem or solve it through the use of this chart, contact your
Icom Dealer or Service Center.
Problem
Possible Cause
Solution
REF�
After your call, the repeater
does not return a status reply.
Transceiver connection is wrong.
When using the Internal Gateway
function, check the connection
between the transceiver and the
router.
When using the External Gateway
function, check the connection
between the transceiver and the
Windows or the Android device.
“Allowed Call Sign” is set to
“Enable.”
When using the Internal Gateway
function, set “Allowed Call Sign”
to “Disable” in the INTERNAL
GATEWAY SETTINGS screen.
When using the External Gateway
function, set “Allowed Call sign”
to “Disable” in the RS-MS3W or
RS-MS3A.
RS-MS3W,
RS-MS3A’s
instruction
manual
When using the External Gateway
function, you did not click (touch)
<Start> in the RS-MS3W or
RS-MS3A.
Click (touch) <Start> in the
RS-MS3W or RS-MS3A.
After your call, the repeater
replies “UR?,” Your own call
sign (MY) and ID suffix “G.”
The call was successfully sent, but
no station immediately replied.
Wait for a while, and try again.
–
After your call, the repeater
replies “RX” or “RPT?” and
Your own call sign (MY) and
ID suffix “G.”
Your call sign (MY) has not been
registered at a gateway server.
Register your call sign (MY) at a
gateway server.
–
The Terminal/AP call sign that is
set in the transceiver, RS-MS3A, or
RS-MS3W has not been registered
in the RS-RP3C as the access
point.
When using the Internal Gateway
function, register the Terminal/
AP call sign that is set in the
transceiver in the RS-RP3C as the
access point.
When using the External Gateway
function, register the Terminal/
AP call sign that is set in the
RS-MS3A or RS-MS3W in the RS-
RP3C as the access point.
The destination station’s call sign
(UR) has not been registered to the
gateway server, or the registered
contents do not match your
transceiver’s setting.
Check the destination station’s
register information.
–
The destination station that uses
the Terminal mode or Access Point
mode does not transmit periodically.
The destination station makes a
call again.
–